Background: Blood pressure (BP) is highest during the day and lowest at night. Absence of this rhythm is a predictor of cardiovascular morbidity and mortality. Contributions of changes in posture and physical activity to the 24-hour day/night rhythm in BP are not well understood. We hypothesized that postural changes and physical activity contribute substantially to the day/night rhythm in BP.
Methods: Fourteen healthy, sedentary, nonobese, normotensive men (aged 19-50 years) each completed an ambulatory and a bed rest condition during which BP was measured every 30-60 minutes for 24 hours. When ambulatory, subjects followed their usual routines without restrictions to capture the "normal" condition. During bed rest, subjects were constantly confined to bed in a 6-degree head-down position; therefore posture was constant, and physical activity was minimized. Two subjects were excluded from analysis because of irregular sleep timing.
Results: The systolic and diastolic BP reduction during the sleep period was similar in ambulatory (-11±2mmHg/-8±1mmHg) and bed rest conditions (-8±3mmHg/-4±2mmHg; P = 0.38/P = 0.12). The morning surge in diastolic BP was attenuated during bed rest (P = 0.001), and there was a statistical trend for the same effect in systolic BP (P = 0.06).
Conclusions: A substantial proportion of the 24-hour BP rhythm remained during bed rest, indicating that typical daily changes in posture and/or physical activity do not entirely explain 24-hour BP variation under normal ambulatory conditions. However, the morning BP increase was attenuated during bed rest, suggesting that the adoption of an upright posture and/or physical activity in the morning contributes to the morning BP surge.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3693479 | PMC |
http://dx.doi.org/10.1093/ajh/hpt026 | DOI Listing |
Viruses
December 2024
Institute of Hygiene and Environmental Medicine, University Medicine Greifswald, Ferdinand-Sauerbruch-Str., 17475 Greifswald, Germany.
Among the physical decontamination methods, treatment with ultraviolet (UV) radiation is a suitable means of preventing viral infections. Mercury vapor lamps (254 nm) used for room decontamination are potentially damaging to human skin (radiation) and harmful to the environment (mercury). Therefore, other UV-C wavelengths (100-280 nm) may be effective for virus inactivation on skin without damaging it, e.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Mechanical Engineering, Brigham Young University, Provo, UT 84602, USA.
Flexible high-deflection strain gauges have been demonstrated to be cost-effective and accessible sensors for capturing human biomechanical deformations. However, the interpretation of these sensors is notably more complex compared to conventional strain gauges, particularly during dynamic motion. In addition to the non-linear viscoelastic behavior of the strain gauge material itself, the dynamic response of the sensors is even more difficult to capture due to spikes in the resistance during strain path changes.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Centro de Estudos Egas Moniz, Faculdade de Medicina, Universidade de Lisboa, 1649-028 Lisbon, Portugal.
Virtual reality (VR) has been used in research and clinical practice in the management of Parkinson's disease (PD), potentially enhancing physiotherapy. Adverse events (AEs) associated with VR applications in PD have been poorly explored. We conducted a randomized controlled trial to compare two 12-week interventions using physiotherapy and immersive VR, and analyzed the frequency and type of AEs occurring in 30 people with PD.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Engineering and Industrial Design, Magdeburg-Stendal University of Applied Sciences, 39110 Magdeburg, Germany.
Inappropriate, excessive, or overly strenuous training of sport horses can result in long-term injury, including the premature cessation of a horse's sporting career. As a countermeasure, this study demonstrates the easy implementation of a biomechanical load monitoring system consisting of five commercial, multi-purpose inertial sensor units non-invasively attached to the horse's distal limbs and trunk. From the data obtained, specific parameters for evaluating gait and limb loads are derived, providing the basis for objective exercise load management and successful injury prevention.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Faculty of Medicine, Department of Kinesiology, Université Laval, Quebec City, QC G1V OA6, Canada.
Foot strike patterns influence vertical loading rates during running. Running retraining interventions often include switching to a new foot strike pattern. Sudden changes in the foot strike pattern may be uncomfortable and may lead to higher step-to-step variability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!