Objective: To evaluated the effect of curing modes and light-cure times on knoop hardness (KH) and microtensile bond strength (µTBS) of dentin adhesives in vitro.
Methods: Twenty molars were made into 80 dentin slices (about 1 mm thick). The dentin slices were prepared with an etch&rinse adhesive A (ONE-STEP PLUS) and a self-etch adhesive B (Clearfil SE Bond), and light-cured respectively under fast mode, i.e.1250 mW/cm(2) light intensity for 10 s, 15 s, 20 s, and ramp mode (soft start curing mode), i.e.initial 0 mW/cm(2) gradually increasing to 1250 mW/cm(2) in first 10 s, then steady for the next 10 s. The prepared dentin slices were kept in dark dry room for 24 h at 37°C, and KH were tested. The other 40 molars were flattened to expose coronal dentin, prepared with adhesives as above. Then the prepared teeth were restored with resin composites incrementally and cured under fast mode. The restored teeth were stored in water for 24 h at 37°C, and slowly sectioned to obtain multiple bonded beams. After 7 d water-storage, the samples received microtensile bond test, and the failure models of beams were observed under a stereomicroscope. Data were analyzed by ANOVA and LSD test (α = 0.05).
Results: No statistical difference in KH [(28.20 ± 5.36), (29.13 ± 5.60), (28.13 ± 4.40), (27.06 ± 3.77) MPa] and µTBS [(22.30 ± 5.07), (22.73 ± 6.59), (26.32 ± 6.17), (25.67 ± 4.31) MPa] of adhesive A were found between four curing conditions (fast mode for 10 s, 15 s, 20 s and ramp mode for 20 s) (P > 0.05). In adhesive B, KH of Fast 20 s [(28.23 ± 3.67) MPa] were significantly higher than those of Fast 10 s [(14.15 ± 2.24) MPa] and Fast 15 s [(17.63 ± 2.17) MPa] (P < 0.05). The µTBS of Fast 20 s [(42.52 ± 3.59) MPa] were significantly higher than those of Fast 10 s [(24.21 ± 3.60) MPa], Fast 15 s [(22.25 ± 4.16) MPa] and Ramp 20 s [(31.12 ± 5.40) MPa] (P < 0.05). In Fast 20 s and Ramp 20 s modes, there were no statistical difference in KH of adhesive A and B, while µTBS of adhesive B were higher than that of adhesive A(P < 0.05).
Conclusions: As for different type dentin adhesives, the appropriate curing time in fast mode is different, and ramp mode (soft start curing mode) has no advantage over fast mode.
Download full-text PDF |
Source |
---|
Anal Chem
January 2025
State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, China.
As the most common and lethal cancer of the female gonads, ovarian cancer (OC) has a grave impact on people's health. OC is asymptomatic, insidious in onset, difficult to diagnose and treat, fast-growing, and easy to metastasize and has poor prognosis and high mortality. How to detect OC as early as possible and treat it without side effects has become a challenging medical problem.
View Article and Find Full Text PDFBiomed Opt Express
January 2025
Dept. of Physics, Kookmin University, Seoul, Republic of Korea.
We present a implementation method of light-sheet microscopy utilizing a highly miniaturized device that produces light-sheet illumination while immersed in the sample container. Our miniaturized plane illuminator (MPI) internally equips a two-axis beam-scanning mechanism based on a magnetostatically driven optical fiber cantilever. A light sheet is produced by fast scanning of the focused beam in an axis while the illumination plane can move in the other axis for positioning and 3D imaging.
View Article and Find Full Text PDFRandom lasers (RLs) with a simple structure and low-cost properties have been recognized as an ideal analytical platform and are still challenging for liquid detecting, remaining beset for low sensitivity, complicated operation, and large analyte consumption. Here, inspired by a microfluidic sensor, a microtubule structured random laser for multifunctional sensing is demonstrated. The random laser is achieved resorting to a curly PMMA film with gain and scatterers embedded in it.
View Article and Find Full Text PDFJ Pharm Biomed Anal
January 2025
Institute of Drug Metabolism and Pharmaceutical Analysis, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310058, China; Jinhua Institute of Zhejiang University, Jinhua 321036, China; State Key Laboratory of Advanced Drug Delivery and Release Systems, Zhejiang University, Hangzhou 310058, China. Electronic address:
A simple and fast LC-MS/MS method was developed and validated for simultaneous quantification of 20 L-amino acids (AAs) in human plasma. Chromatographic separation was achieved on an Agilent AdvanceBio Hilic column within 15 min via gradient elution with an aqueous solution containing 5 mM ammonium formate, 5 mM ammonium acetate and 0.1 % formic acid and an organic mobile phase containing 0.
View Article and Find Full Text PDFAn Acad Bras Cienc
January 2025
University of Technology, Department of Control and System Engineering, Baghdad, 10066, Iraq.
Latency in flux observation has an adverse effect on the performance of observer-based field-oriented speed control for three-phase induction motor (IM). The reduction of the convergent rate of estimation errors could improve the performance of speed-controlled IM based on flux observers. The main contribution is to design a fast convergent flux observer, which provides bounded estimation error immediately after one instant of motor startup.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!