Objective: To investigate the influence of the diameter and length of the mini-implant on the primary stability after loading with composite forces (CF) which contained torque and horizontal forces (HF).
Methods: Ninety-six finite element models were established by the combination of mini-implant and bone, diameters (1.2 mm, 1.6 mm, 2.0 mm) and length (6 mm, 8 mm, 10 mm, 12 mm). There were 12 sizes, each size corresponded with 8 models. Group HF (each size n = 4) was loaded with 1.96 N horizontal force and Group CF (each size n = 4) was loaded with composite force which contained 6 N·mm torque and 1.96 N horizontal force. The maximum displacement of mini-implant with different force directions, implant diameters and lengths were evaluated.
Results: The effect of force direction on the displacement related to diameter of mini-implant. The maximum displacement under load with HF respectively was changed with the changing of diameter[1.2 mm: (7.71 ± 0.49) µm; 1.6 mm: (3.94 ± 0.31) µm; 2.0 mm: (2.32 ± 0.43) µm], which were smaller than the maximum displacement of Group CF [1.2 mm: (9.22 ± 0.63) µm; 1.6 mm: (4.62 ± 0.52) µm; 2.0 mm: (2.69 ± 0.49) µm] (P < 0.05). When diameter was 1.2 mm, the difference of the maximum displacement [(1.61 ± 0.22) µm] between Group HF and CF was more obvious than that when the diameter was 1.6 mm or 2.0 mm [(0.64 ± 0.12), (0.49 ± 0.06) µm] (P < 0.05).
Conclusions: The composite force had unfavorable effect on the primary stability of the mini-implant. The diameter of the mini-implant had better be larger than 1.2 mm when the composite forces were applied.
Download full-text PDF |
Source |
---|
Sensors (Basel)
December 2024
Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-537 Lodz, Poland.
This paper is devoted to the development of a window-type inductive current transformer (iCT) with a rated primary current equal to 400 A and two secondary windings with rated currents of 5 A and 1 A. Its novelty concerns the presentation of this process in the case of an iCT with a 0.2S accuracy class ensured not only for a sinusoidal current of a frequency of 50 Hz but also for the transformation of distorted current in the harmonic frequency range from 50 Hz to 5 kHz.
View Article and Find Full Text PDFMicromachines (Basel)
December 2024
Department of Applied Mechanics, Faculty of Civil Engineering, Vilnius Gediminas Technical University, LT-10223 Vilnius, Lithuania.
This paper presents the design, development, and investigation of a novel piezoelectric inertial motor whose target application is the low Earth orbit (LEO) temperature conditions. The motor utilizes the inertial stick-slip principle, driven by the first bending mode of three piezoelectric bimorph plates, and is compact and lightweight, with a total volume of 443 cm and a mass of 28.14 g.
View Article and Find Full Text PDFLife (Basel)
December 2024
Department of Cranio-Maxillofacial Surgery, Oral Surgery and Implantology, Medical University of Warsaw, 02-005 Warsaw, Poland.
The objective of this study was to compare single-needle arthrocentesis with the conventional two-needle arthrocentesis, as well as the additional intracapsular injection of hyaluronic acid or platelet-rich fibrin. A total of 96 patients with established osteoarthritis (OA) ( = 48) or with internal de-arrangement (DD) ( = 48) were assigned single-needle arthrocentesis with distension of the joint or conventional two-needle arthrocentesis with or without intracapsular injection of the medication (hyaluronic acid (HA) or platelet-rich plasma (PRP)) performed every month over a period of 6 months. The maximum mouth opening and pain, as measured by the visual analog scale (VAS), were compared.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Pediatric Orthopedic Hospital, Honghui Hospital, Xi'an Jiao tong University, Xi'an, 710000, China.
Background: Supracondylar humerus fractures (SCHFs) are the most common elbow fractures in children and are typically treated with closed reduction and Kirschner pin fixation. However, varying degrees of residual rotational displacement may remain after closed reduction. Several methods exist to assess rotational displacement, but none account for the effect of elbow rotation on the results.
View Article and Find Full Text PDFJ Vis Exp
December 2024
School of Engineering and Materials Science, Queen Mary University of London.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!