Objective: To verify whether peripheral blood circulation and arterial wall distensibility are influenced by atmospheric pressure (AtPr) and to examine if their association is dependent on age and/or sex.
Methods: Associations among natural AtPr levels (on the examination day as well as 1 and 2 days prior), limb muscle hemodynamics, and distensibility of conduit arteries were retrospectively examined in an observational study of 276 untreated patients with primary moderate hypertension (mean age 56.4 years, 194 men). Forearm and calf circulations at rest and 3 min after ischemia were measured by venous occlusion plethysmography. Compliance of the brachial and shank arteries was assessed by oscillometry.
Results: After adjustment for age, degree of hypertension, and season, correlation and multiple regression analyses revealed a season-independent but age-dependent direct correlation between the stiffness of limb arteries and AtPr levels on the examination day in men, but not women. The association weakened with the degree of hypertension, disappeared with age, and was more evident in the arms than in the legs.
Conclusion: Parameters of arterial wall distensibility in adult hypertensive men are susceptible to AtPr changes within the usually observed limits (730-770 mmHg). It is proposed that reduction of arterial wall barometric responsiveness in women and aging men is a likely mechanism underlying their meteosensitivity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3967/0895-3988.2013.04.007 | DOI Listing |
Theranostics
January 2025
Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany.
To establish the extent, distribution and frequency of in-vivo vessel wall [Ga]Ga-PentixaFor uptake and to determine its relationship with calcified atherosclerotic plaque burden (CAP) and cardiovascular risk factors (CVRF). 65 oncological patients undergoing [Ga]Ga-PentixaFor PET/CT were assessed. Radiotracer uptake (target-to-background ratio [TBR]) and CAP burden (including number of CAP sites, calcification circumference and thickness) in seven major vessel segments per patient were determined.
View Article and Find Full Text PDFJ Pain Res
January 2025
Department of Anesthesiology, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, 100043, People's Republic of China.
Objective: To evaluate the clinical efficacy and safety of ultrasound-guided rectus sheath block (RSB) in laparoscopic umbilical hernia repair with intraperitoneal onlay mesh (IPOM).
Methods: A total of 139 patients scheduled for laparoscopic umbilical hernia repair with IPOM were selected and randomly assigned to either the group receiving general anesthesia combined with bilateral rectus sheath block (Group GR, 71 patients) or the group receiving general anesthesia alone (Group G, 68 patients). We monitored the patients' heart rate (HR) and mean arterial pressure (MAP) at four time points: before anesthesia induction (T1), at the start of surgery (T2), during mesh fixation (T3), and upon removal of the laryngeal mask (T4).
Bioengineering (Basel)
November 2024
University of Electronic Science and Technology of China, Chengdu 611731, China.
Aneurysm modeling and simulation play an important role in many specialist areas in the field of medicine such as surgical education and training, clinical diagnosis and prediction, and treatment planning. Despite the considerable effort invested in developing computational fluid dynamics so far, visual simulation of blood flow dynamics in aneurysms, especially the under-explored aspect of bifurcation aneurysms, remains a challenging issue. To alleviate the situation, this study introduces a novel Smoothed Particle Hydrodynamics (SPH)-based method to model and visually simulate blood flow, bifurcation progression, and fluid-structure interaction.
View Article and Find Full Text PDFBiomedicines
December 2024
Department of Physiology and Cell Biology, University of South Alabama College of Medicine, Mobile, AL 36688, USA.
Background: Small conductance Ca activated K channels (K2.3) are important regulators of vascular function. They provide Ca-dependent hyperpolarization of the endothelial membrane potential, promoting agonist-induced vasodilation.
View Article and Find Full Text PDFJ Hazard Mater
January 2025
Department of Toxicology, School of Public Health, Hebei Medical University, Shijiazhuang 050017, China; Hebei Key Laboratory of Environment and Human Health, Shijiazhuang, Hebei 050017, China; The Key Laboratory of Neural and Vascular Biology, Ministry of Education, Hebei Medical University, Shijiazhuang 050017, China. Electronic address:
6:2 Chlorinated polyfluorinated ether sulfonate (6:2 Cl-PFESA; trade name F-53B) is an alternative to perfluorooctane sulfonate (PFOS) and is widely detected in various environmental media and biological samples. Polystyrene nanoplastics (PS-NPs) have become a significant pollutant in the global environment. However, the comprehensive effects of both on the vascular system of mammals are still unclear.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!