Atrophic mandible fractures are frequently a challenge to stabilize. This study evaluated, through mechanical testing in vitro, the number of locking screws that is sufficient to withstand loading when applied with a locking reconstruction plate in the fixation of atrophic mandible fractures. Polyurethane mandibles with a simulated linear fracture at the midline were used as substratum. Results show that resistance of the fixation is poor when one and two screws are used on each side of the fracture. Three screws on each side of the fracture significantly increases the resistance to displacement. However, no additional strength is added to the construct when more than three screws per side are used.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijom.2013.02.010DOI Listing

Publication Analysis

Top Keywords

screws side
12
atrophic mandible
8
mandible fractures
8
side fracture
8
three screws
8
number screws
4
screws stability
4
stability locking
4
locking mandibular
4
mandibular reconstruction
4

Similar Publications

 Instrumentation of C2 vertebra is considered the most difficult for young neurosurgeons and trainees due to its complex anatomical structures, variety of surgical approaches and techniques, and proximity to important neurovascular structures. Key points from a surgical perspective for midline posterior approach is described in the era of neuroradiological advancements.  Computed tomography angiographies (CTAs) of a total of 92 patients were evaluated with special attention to the key findings for insertion of screws for craniovertebral junction (CVJ) fixations.

View Article and Find Full Text PDF

A patient in his early adolescence, who was treated for T5-T6 tubercular spondylodiscitis with an un-instrumented decompression, presented at 36 months post-index surgery, for post-laminectomy instability and kyphosis, after completing his requisite antitubercular treatment. He underwent thoracic posterior instrumented kyphosis correction and anterior reconstruction, with a T5-T6 partial corpectomy and corpectomy spacer placement, through a posterior midline incision. On the second postoperative day, he started complaining of pain on the left side of his chest, abdomen and left shoulder.

View Article and Find Full Text PDF

Background: Coronary sinus (CS) lead placement in persistent left superior vena cava (PLSVC) cases is challenging because of the poor backup force of the guiding catheter within the enlarged CS. Active fixation Quadripolar leads (Attain Stability™ Quad 4798, Medtronic) can expand choice to CS branches with limited access; however, no cases of anchoring to the main body of the CS have been published to date.

Case Summary: We describe a case of cardiac resynchronization therapy pacemaker upgrade in a 79-year-old female who developed pacing-induced cardiomyopathy after pacemaker implantation via the right superior vena cava (SVC) for atrioventricular block eight years ago wherein PLSVC was revealed during the procedure.

View Article and Find Full Text PDF

Fruit seeds are often an underutilized side-stream of fruit processing. The most common approach to seed valorization is oil extraction due to the relative simplicity of the process. The partially or fully defatted seed meal is rarely further processed, even though seeds generally contain more protein and fiber than oil.

View Article and Find Full Text PDF

(1) Background: The incidence of fragility fractures of the pelvis (FFP) has increased significantly over the past decades. Unilateral non-displaced fractures, defined as FFP II, are the most common type of fracture. When conservative treatment fails, surgical treatment is indicated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!