Particle size characterization of aerosols generated during surface contaminated concrete demolition.

Health Phys

Idaho State University, School of Engineering, 921 S. 8 th Ave., Mail Stop 8060, Pocatello, ID 83209, USA.

Published: May 2013

The purpose of this study was to measure mass and activity distributions from the aerosols generated during the demolition of surface contaminated concrete. Air samples were collected using a cascade impactor during the mechanical hammering and dismantlement of radiologically contaminated high level waste process vaults from which the piping and components had been previously removed. The experimentally determined distribution parameters were compared with the 5.0-μm particle size referenced in the U.S. Department of Energy (U.S. DOE) regulations pertaining to internal deposition (10CFR835 and ICRP66). Mass distribution parameters were compared with their activity distribution counterparts. The Mass Median Aerodynamic Diameter (MMAD) was determined to be 4.2 μm with a Mass Geometric Standard Deviation (GSDM) of 2.3 μm, and the Co Activity Median Aerodynamic Diameter (AMAD) was determined to be 3.9 μm with an Activity Geometric Standard Deviation (GSDA) of 2.3 μm. These results are consistent with the ICRP66 5.0-μm reference particle size and the Derived Air Concentration (DAC) values referenced in 10CFR835 and utilized throughout the U.S. DOE complex.

Download full-text PDF

Source
http://dx.doi.org/10.1097/HP.0b013e318287321dDOI Listing

Publication Analysis

Top Keywords

particle size
12
aerosols generated
8
surface contaminated
8
contaminated concrete
8
distribution parameters
8
parameters compared
8
median aerodynamic
8
aerodynamic diameter
8
determined μm
8
geometric standard
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!