Objective: To evaluate the time course of the recovery of transverse strain in the Achilles and patellar tendon following a bout of resistance exercise.

Methods: Seventeen healthy adults underwent sonographic examination of the right patellar (n=9) and Achilles (n=8) tendons immediately prior to and following 90 repetitions of weight-bearing quadriceps and gastrocnemius-resistance exercise performed against an effective resistance of 175% and 250% body weight, respectively. Sagittal tendon thickness was determined 20 mm from the enthesis and transverse strain, as defined by the stretch ratio, was repeatedly monitored over a 24 h recovery period.

Results: Resistance exercise resulted in an immediate decrease in Achilles (t7=10.6, p<0.01) and patellar (t8=8.9, p<0.01) tendon thickness, resulting in an average transverse stretch ratio of 0.86±0.04 and 0.82±0.05, which was not significantly different between tendons. The magnitude of the immediate transverse strain response, however, was reduced with advancing age (r=0.63, p<0.01). Recovery in transverse strain was prolonged compared with the duration of loading and exponential in nature. The average primary recovery time was not significantly different between the Achilles (6.5±3.2 h) and patellar (7.1±3.2 h) tendons. Body weight accounted for 62% and 64% of the variation in recovery time, respectively.

Conclusions: Despite structural and biochemical differences between the Achilles and patellar tendon, the mechanisms underlying transverse creep recovery in vivo appear similar and are highly time dependent. These novel findings have important implications concerning the time required for the mechanical recovery of high-stress tendons following an acute bout of exercise.

Download full-text PDF

Source
http://dx.doi.org/10.1136/bjsports-2012-091707DOI Listing

Publication Analysis

Top Keywords

transverse strain
12
time course
8
recovery transverse
8
course vivo
4
vivo recovery
4
strain high-stress
4
high-stress tendons
4
tendons exercise
4
exercise objective
4
objective evaluate
4

Similar Publications

Metagenomics-based tracing of genetically modified microorganism contaminations in commercial fermentation products.

Food Chem (Oxf)

June 2025

Sciensano, Transversal activities in Applied Genomics (TAG), J. Wytsmanstraat 14, 1050 Brussels, Belgium.

Genetically modified microorganisms (GMM) are frequently employed for the production of microbial fermentation products such as food enzymes. Although presence of the GMM or its recombinant DNA in the final product is not authorized, contaminations occur frequently. Insight into the contamination source of a GMM is of crucial importance to allow the competent authorities to take appropriate action.

View Article and Find Full Text PDF

Piezovoltages generated by ZnO nano/microwire bending and strain enable electronic biogenerators that harvest human body movement to power-implanted biomedical devices. Currently, low voltages generated by these biogenerators limit their use to replace today's biomedical batteries. Electrically charged native point defects inside ZnO microwires can control these macroscopic piezo voltages, generating transverse electric fields that couple with strained wires' lengthwise piezoelectric fields so they redistribute spatially and change voltage output.

View Article and Find Full Text PDF

Rhus chinensis, a deciduous tree of the genus Rhus (family Anacardiaceae), is widely cultivated in China for its medicinal, edible, and ornamental value (Zhang et al., 2022). In April 2022, symptoms of winged leaf dieback disease were observed at Southwest Forestry University in Kunming, Yunnan Province, China (E102°45'42.

View Article and Find Full Text PDF

Aim: Left atrial (LA) strain is emerging as a valuable metric for evaluating cardiac function, particularly under pathological conditions such as pressure overload. This preclinical study investigates the predictive utility of LA strain on cardiac function in a murine model subjected to pressure overload, mimicking pathologies such as hypertension and aortic stenosis.

Methods: High-resolution ultrasound was performed in a cohort of mice (n = 16) to evaluate left atrial and left ventricular function at baseline and 2 and 4 weeks after transverse aortic constriction (TAC).

View Article and Find Full Text PDF

Stretchable microwave absorbers (SMAs) are vital for flexible electronics. Traditional SMAs display unstable tensile properties resulting from inconsistencies between the constrained conductive layer and the flexible dielectric layer. This study introduces an organohydrogel-based stretchable microwave absorber (OSMA) that incorporates an organohydrogel within an island-bridge structure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!