Normal range of facial asymmetry in spherical coordinates: a CBCT study.

Imaging Sci Dent

Department of Oral and Maxillofacial Radiology, School of Dentistry, Dental Science Research Institute, Chonnam National University, Gwangju, Korea.

Published: March 2013

Purpose: This study aimed to measure the bilateral differences of facial lines in spherical coordinates from faces within a normal range of asymmetry utilizing cone-beam computed tomography (CBCT).

Materials And Methods: CBCT scans from 22 females with normal symmetric-looking faces (mean age 24 years and 8 months) were selected for the study. The average menton deviation was 1.01±0.66 mm. The spherical coordinates, length, and midsagittal and coronal inclination angles of the ramal and mandibular lines were calculated from CBCT. The bilateral differences in the facial lines were determined.

Results: All of the study subjects had minimal bilateral differences of facial lines. The normal range of facial asymmetry of the ramal and mandibular lines was obtained in spherical coordinates.

Conclusion: The normal range of facial asymmetry in the spherical coordinate system in this study should be useful as a reference for diagnosing facial asymmetry.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3604368PMC
http://dx.doi.org/10.5624/isd.2013.43.1.31DOI Listing

Publication Analysis

Top Keywords

normal range
16
facial asymmetry
16
range facial
12
spherical coordinates
12
bilateral differences
12
differences facial
12
facial lines
12
asymmetry spherical
8
lines spherical
8
ramal mandibular
8

Similar Publications

Using Virtual Reality to Promote Self-Identity Reconstruction as the Main Focus of Therapy.

J Clin Psychol

January 2025

Department of Clinical Psychology and Psychobiology, The Institute of Neurosciences, Universitat de Barcelona, Barcelona, Spain.

Based on the repertory grid technique, we developed Explore Your Meanings (EYME), a digital platform that helps patients explore identity values and internal conflicts using virtual reality (VR). EYME was part of a research project treating depression in young adults, including 10 weekly, 1-h sessions aimed at changing personal constructs-cognitive schemas that shape how individuals interpret reality. We present the case of Mary, a 21-year-old woman diagnosed with persistent major depressive disorder and social phobia.

View Article and Find Full Text PDF

Purpose: Carcinoembryonic antigen (CEA) is an important prognostic factor for rectal cancer. This study aims to introduce a novel cutoff point for CEA within the normal range to improve prognosis prediction and enhance patient stratification in rectal cancer patients.

Methods: A total of 316 patients with stages I to III rectal cancer who underwent surgical tumor resection were enrolled.

View Article and Find Full Text PDF

Target-regulated AgS/FeOOH heterojunction activity: a direct label-free photoelectrochemical immunosensor.

Mikrochim Acta

January 2025

College of Geography and Environmental Sciences, College of Chemistry and Materials Science, Zhejiang Normal University, Jinhua, 321004, China.

Myoglobin (Mb), an important cardiac marker, plays a crucial role in diagnosing, monitoring, and evaluating the condition of patients with cardiovascular diseases. Here, we propose a label-free photoelectrochemical (PEC) sensor for the detection of Mb through target regulated the photoactivity of AgS/FeOOH heterojunction. The AgS/FeOOH nanospindles were synthesized and served as a sensing platform for the fabrication of bio-recognized process for Mb.

View Article and Find Full Text PDF

In recent years, there has been a global threat from emerging vector-borne diseases (VBD), despite the implementation of several vector control programs. Considering the benefits of bacterial pesticides, the present study aimed to isolate potential mosquitocidal bacteria from the various soil types collected from the Kasaragod (12.5°N, 75.

View Article and Find Full Text PDF

Introduction/aims: The standard procedure to establish reference values in a neuromuscular laboratory involves examining healthy controls, as nerve size varies with the population and muscle echo intensity (EI) is device-specific. We aimed to derive these reference values by extrapolation from a studied sample (the e-norms method), compare them with published reference values, and determine their diagnostic accuracy.

Methods: We retrospectively analyzed data from consecutive patients who underwent nerve and/or muscle ultrasound in our ultrasound laboratory, which is a tertiary referral center for neuromuscular diseases in Southern Poland in the years 2018-2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!