AI Article Synopsis

  • * After a minimum of 10 years, the survivorship rates were excellent, with 100% for the femoral stem and 97.5% for the entire prosthesis; patient satisfaction scores significantly improved.
  • * Radiographic assessments showed no notable issues with the implant fixation, indicating good long-term stability and low levels of thigh pain experienced by patients.

Article Abstract

This is a retrospective, non-comparative study of 212 consecutive patients who underwent Total Hip Arthroplasty with an uncemented hydroxyapatite (HA) coated stem system from November 1997 to March 2000. The objective of the study was to analyze the performance of the implant at a minimum of 10 years in older patients (mean age 79.6 years). The Kaplan-Meier survivorship of the femoral stem at 10 years was 100%, and 97.5% for the whole prosthesis. The mean Merle d'Aubigné clinical score improved from 4.4 ± 2.1 points pre-operatively to 13.39 ± 3.77 points at final follow-up (p<0.05), and the mean VAS score for thigh pain was 1.25. The radiographic analysis showed that there were no significant radiolucent lines or osteolysis compromising the fixation of the implant.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2012.11.008DOI Listing

Publication Analysis

Top Keywords

femoral stem
8
minimum year
4
year survivorship
4
survivorship analysis
4
analysis partially
4
partially coated
4
coated hydroxyapatite
4
hydroxyapatite tapered
4
tapered femoral
4
stem elderly
4

Similar Publications

Background: Microfracture drilling is a surgical technique that involves creating multiple perforations in areas of cartilage defects to recruit stem cells from the bone marrow, thereby promoting cartilage regeneration in the knee joint. Increasing the exposed bone marrow surface area (more holes in the same area) can enhance stem cell outflow. However, when the exposed area is large, it may affect the mechanical strength of the bone at the site of the cartilage defect.

View Article and Find Full Text PDF

Viscoelastic hydrogel combined with dynamic compression promotes osteogenic differentiation of bone marrow mesenchymal stem cells and bone repair in rats.

Regen Biomater

November 2024

Medical 3D Printing Center, Orthopedic Institute, Department of Orthopedic Surgery, The First Affiliated Hospital, Suzhou Medical College, Soochow University, Suzhou, Jiangsu 215000, PR China.

A biomechanical environment constructed exploiting the mechanical property of the extracellular matrix and external loading is essential for cell behaviour. Building suitable mechanical stimuli using feasible scaffold material and moderate mechanical loading is critical in bone tissue engineering for bone repair. However, the detailed mechanism of the mechanical regulation remains ambiguous.

View Article and Find Full Text PDF

Thermoresponsive dual-network chitosan-based hydrogels with demineralized bone matrix for controlled release of rhBMP9 in the treatment of femoral head osteonecrosis.

Carbohydr Polym

March 2025

Key Lab of Modern Toxicology of Ministry of Education, Center for Global Health, School of Public Health, Nanjing Medical University, 101 Longmian Avenue, Nanjing 211166, China. Electronic address:

In an effort to mitigate or reverse the pathological progression of early-stage osteonecrosis of the femoral head (ONFH), this study employed a promising strategy that involves the sustained delivery of osteogenic factors to augment core decompression, facilitated by the use of composite hydrogels. Specifically, a hydrogel was synthesized by blending chitosan, Pluronic F-127, and tripolyphosphate, utilizing both ionic bonding and copolymer micelle cross-linking techniques. This hydrogel demonstrated exceptional biocompatibility, temperature responsiveness, pH-dependent biodegradation, and controlled release properties.

View Article and Find Full Text PDF

Background: The debate continues on whether combining core decompression (CD) with regenerative therapy provides a more effective treatment for early femoral head necrosis than CD alone. This systematic review and meta-analysis endeavored to assess its efficacy.

Methods: We systematically searched PubMed, Web of Science, and Cochrane Library through July 2024 for RCTs and cohort studies evaluating the impact of core decompression (CD) with regenerative therapy versus CD alone in early-stage osteonecrosis (ARCO I, II or IIIa or Ficat I or II) of the femoral head (ONFH).

View Article and Find Full Text PDF

Bone defects are difficult to treat clinically and most often require bone grafting for repair. However, the source of autograft bone is limited, and allograft bone carries the risk of disease transmission and immune rejection. As tissue engineering technology advances, bone replacement materials are playing an increasingly important role in the treatment of bone defects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!