A systematic review of the literature was undertaken to evaluate the outcomes and complications following proximal femoral arthroplasty for primary or metastatic tumors affecting the proximal femur. Six hundred sixty-eight patients were available for review. The length of resection ranged from 92 to 212 mm. Limb salvage rate reached over 90%. At 5 years the implant survival rate was 84% and at 10 years, it was 70%. The overall revision rate was 11.1%. Prevalence of venous thrombo-embolic (VTE) events was 8.5%, dislocation rate was 5.8%, infection was 5.2%, local tumor reoccurrence was 4.7%, perioperative mortality was 1.5%, and periprosthetic fracture was 0.6%. Where it was provided the Musculoskeletal Tumour Score was 70.8%. The implants tend to outlive patients with metastatic disease and high-grade localized disease, providing them with a relatively pain-free limb with good mobility and quality of life.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2012.10.024DOI Listing

Publication Analysis

Top Keywords

proximal femoral
8
femoral arthroplasty
8
systematic review
8
implant longevity
4
longevity complications
4
complications functional
4
functional outcome
4
outcome proximal
4
arthroplasty musculoskeletal
4
musculoskeletal tumors
4

Similar Publications

Objective: Reverse obliquity intertrochanteric fracture is an unstable type of fracture. Current guidelines recommend intramedullary fixation, but there are still complications such as screw removal, hip varus, nail withdrawal, and nail fracture. The objective of this study was to use finite element analysis to compare the biomechanical properties of the novel proximal femoral bionic nail (PFBN), proximal femoral nail antirotation (PFNA), and combined compression interlocking intramedullary nail (InterTan) in the treatment of reverse obliquity intertrochanteric fractures (AO/OTA 31-A3.

View Article and Find Full Text PDF

Background: Long-leg alignment and joint line obliquity have traditionally been assessed using two-dimensional (2D) radiography, but the accuracy of this measurement has remained unclear. This study aimed to evaluate the accuracy of 2D measurements of lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA) using upright three-dimensional (3D) computed tomography (CT).

Methods: This study involved 66 knees from 38 patients (34 women, four men) with knee osteoarthritis (OA), categorized by Kellgren-Lawrence (KL) grade.

View Article and Find Full Text PDF

The best treatment method for reverse obliquity intertrochanteric fractures (ROIFs) is still under debate. Our team designed the modified proximal femoral nail (MPFN) specially for treating such fractures. The objective of this research was to introduce the MPFN device and compare the biomechanical properties with Proximal Femoral Nail Antirotation (PFNA) and InterTAN nail via finite element modelling.

View Article and Find Full Text PDF

Purpose: The fixation method commonly employed worldwide for treating unstable fractures of the posterior pelvic ring is the percutaneous iliosacral screw technique. However, prolonged operation time and frequent fluoroscopies result in surgical risks. This study aimed to investigate whether a new triangulation method could reduce operative and fluoroscopy times and increase the accuracy of screw placement.

View Article and Find Full Text PDF

Osteoporosis is the most common bone metabolic unbalance, leading to fragility fractures, which are known to be associated with structural changes in the bone. Cortical bone accounts for 80 % of the skeleton mass and undergoes remodeling throughout life, leading to changes in its thickness and microstructure. Although many studies quantified the different cortical bone structures using CT techniques (3D), they are often realised on a small number of samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!