(99m) Tc-labelled human serum albumin cannot replace (125) I-labelled human serum albumin to determine plasma volume in patients with liver disease.

Clin Physiol Funct Imaging

Clinical Physiology and Nuclear Medicine 239, Center of Functional and Diagnostic Imaging and Research, Hvidovre Hospital, University of Copenhagen, Copenhagen, Denmark.

Published: May 2013

Background And Aims: Determination of plasma volume (PV) is important in several clinical situations. Thus, patients with liver disease often have augmented PV as part of their sodium-water retention. This study was undertaken to compare PV determination by two indicators: technetium-labelled human serum albumin ((99m) Tc-HSA) and iodine-labelled human serum albumin ((125) I-HSA), as the former may have advantages at repeated measurements and the latter is the classical gold standard.

Study Population And Methods: In 88 patients, (64 with liver disease, mainly cirrhosis, and 24 patients without liver disease), simultaneous measurements of PV were taken with (99m) Tc-HSA and (125) I-HSA after 1 h in the supine position. Blood samples were obtained before and 10 min after quantitative injection of the two indicators. In a subset of patients (n = 32), the measurements were repeated within 1 h.

Results: In all patients, a close correlation was present between PV determined by the two indicators (r = 0·89, P<0·0001). In all, but twelve patients, a higher PV was obtained with (99m) Tc-HSA compared with (125) I-HSA (P<0·0001). PV determined with (99m) Tc-HSA exceeded PV determined with (125) I-HSA by 367 ml (5·2 ml kg(-1) ) in liver patients as compared to 260 ml (3·5 ml kg(-1) ) in patients without liver disease (P<0·05). The precision of repeated PV determination was 1·75% (coefficient of variation) with (99m) Tc-HSA and 1·71% with (125) I-HSA (ns), and similar values were found in patients with and without liver disease.

Conclusion: The study demonstrates that (99m) Tc-HSA has the same precision as that of (125) I-HSA. However, especially in patients with liver disease, (99m) Tc-HSA consistently overestimates the PV, most likely owing to indicator heterogeneity with subsequent fast removal from the circulating medium with a higher volume of distribution as the outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cpf.12015DOI Listing

Publication Analysis

Top Keywords

human serum
16
serum albumin
16
patients liver
16
liver disease
16
plasma volume
8
99m tc-hsa
8
125 i-hsa
8
patients
6
99m tc-labelled
4
human
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!