"Dynamic spot sign" on CT perfusion source images predicts haematoma expansion in acute intracerebral haemorrhage.

Eur Radiol

Department of Neuroradiology, Beijing Neurosurgical Institute, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.

Published: July 2013

Objectives: To evaluate the association between dynamic progressive enhancing foci ("dynamic spot sign") in acute haematoma on CT perfusion source images (CTP-SI) and haematoma expansion.

Methods: One hundred twelve consecutive patients with spontaneous intracerebral haemorrhage according to unenhanced CT, CTP and CT angiography within 6 h of symptom onset were prospectively evaluated. Patients were dichotomised according to the presence/absence of the dynamic spot sign on CTP-SI in haematoma. The predictive value of haematoma expansion was analysed.

Results: Haematoma expansion was detected in 28 patients (25.0 %) on follow-up unenhanced CT images. Thirty patients (26.8 %) demonstrated the dynamic spot sign on CTP-SI, about 83.3 % of patients with haematoma expansion (P < 0.001). Sensitivity, specificity, positive predictive value, negative predictive value and kappa value for expansion were 89.3 %, 94.0 %, 96.3 %, 83.3 % and 0.814, respectively. In multiple regression, the presence of the CTP dynamic spot sign within acute haematomas independently predicted haematoma expansion; the univariate analysis OR value was 131.667 (29.386-590.289), P < 0.0001. Moreover, the multivariate analysis CTP dynamic spot sign OR value was 203.996 (32.123-1295.488), P < 0.0001.

Conclusions: The CTP-SI dynamic spot sign is associated with acute haematoma expansion, is more direct in showing active ongoing bleeding and has a higher predictive value than the CTA spot sign.

Key Points: • It is important to identify potential progression of spontaneous intracerebral haemorrhage. • Dynamic enhancement within CT perfusion source images is associated with haemorrhage expansion. • The CTP dynamic spot sign may be present throughout arterial to venous phase imaging. • The CTP dynamic spot sign carries a higher predive value for haematoma expansion than CTA.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-013-2803-4DOI Listing

Publication Analysis

Top Keywords

haematoma expansion
16
"dynamic spot
8
spot sign"
8
perfusion source
8
source images
8
intracerebral haemorrhage
8
ctp-si haematoma
8
dynamic spot
8
spot sign
8
sign ctp-si
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!