A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A new distraction arthroplasty device using magnetic force; a cadaveric study. | LitMetric

Background: It is difficult for an articular cartilage injury to repair spontaneously. There are many procedures for treating cartilage injury, however there is no standard procedure for middle-aged patients who have diffuse knee osteoarthritis, especially of the lateral compartment. Therefore, Ochi developed a new distraction device that uses magnetic power to enlarge a joint space and promote cartilage regeneration with microfracture. The purpose of this study is to evaluate this new distraction arthroplasty system by using the cadaveric knee.

Methods: This study used ten knees from six cadavers that were embalmed by Thiel's methods. The medial and lateral joint space was measured by AP radiographic view before and after distraction, and after weight-bearing to evaluate the joint distraction. The contact pressure of the medial and lateral compartments at the knee extension position by using a prescale film system was measured before and after weight-bearing with a 15 or 30-kg weight-bearing load to evaluate the effectiveness of this device.

Findings: The lateral joint space significantly increased from the pre-distraction to the post-distraction; however, it did not change significantly between post-distraction and post-weight-bearing. With a 15 or 30-kg weight-bearing load, the contact pressure of the lateral compartment significantly decreased from the pre-distraction to the post-distraction.

Interpretation: The most important advantage of this device is that it maintains a continuous distraction tension and enables almost the full range of motion of the knee. We believe that joint distraction by using magnetic force can be a promising option for cartilage injury in middle-aged patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinbiomech.2013.02.003DOI Listing

Publication Analysis

Top Keywords

cartilage injury
12
joint space
12
distraction arthroplasty
8
device magnetic
8
magnetic force
8
middle-aged patients
8
lateral compartment
8
medial lateral
8
lateral joint
8
joint distraction
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!