A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Advantages of real time three-dimensional echocardiography in the assessment of right ventricular volumes and function in patients with pulmonary hypertension compared with conventional two-dimensional echocardiography. | LitMetric

Background: In recent years, right ventricular (RV) function has acquired greater relevance as a clinical and prognostic marker in many physiopathological conditions. The study aims to point out the value of real time three-dimensional echocardiography (RT3DE) and tissue Doppler imaging (TDI) in the evaluation of patients affected by pulmonary hypertension (PH), compared with conventional two-dimensional (2D) echocardiography.

Methods: We enrolled 44 subjects affected by PH who underwent 2D and Doppler echocardiography, RT 3D Echocardiography and TDI evaluation of the RV, and a healthy control group. PH itself can induce severe functional and structural abnormalities of the RV, such as RV hypertrophy, RV dilation, and RV systolic and diastolic dysfunction.

Results: In this study, RV FAC, and TAPSE showed marked alterations in patients with PH compared to the control group (C): (RVFAC: [PH] 0.29 ± 0.07 vs. [C] 0.49 ± 0.05%, P < 0.0001; TAPSE: [PH] 15.3 ± 3.2 vs. [C] 21.1 ± 2.6 mm, P > 0.0001). The 3D RV end-diastolic volume was significantly higher in PH than in C (PH) (138.7 ± 25.3 vs. [C] 82.8 ± 12.5 mL, P < 0.0001] as well as 3D RV end-systolic volume (PH) (97.6 ± 21.5 vs. [C] 39.3 ± 9.5 mL, P < 0.0001). The 3D RV ejection fraction (EF) was significantly lower in the pulmonary hypertension group than in healthy subjects (31.8 ± 6.8 vs. [C] 52.5 ± 4.7%, P < 0.0001).

Conclusions: In patients with PH, evaluation of the RV diastolic and systolic volume and EF by RT3DE has shown a higher discriminating power in comparison, respectively, with 2DRV diastolic area and the relative fractional area changes.

Download full-text PDF

Source
http://dx.doi.org/10.1111/echo.12137DOI Listing

Publication Analysis

Top Keywords

pulmonary hypertension
12
real time
8
time three-dimensional
8
three-dimensional echocardiography
8
patients pulmonary
8
hypertension compared
8
compared conventional
8
conventional two-dimensional
8
tdi evaluation
8
control group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!