A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Exhaled nitric oxide and other major exhaled compounds for the diagnosis of metabolic diseases. | LitMetric

Background: Many metabolic diseases including obesity, cardiovascular disease and diabetes share common pathogenetic pathways, which may involve chronic oxidative stress and inflammation. There is increasing evidence that assessment of biomarkers on exhaled gases or exhaled breath condensate may serve as a non-invasive tool to detect abnormalities in metabolic diseases mirroring increased in oxidative stress, systemic inflammation and endothelial dysfunction.

Methods: Among commonly used exhaled biomarkers, nitric oxide (NO) on exhaled air and some constituents of exhaled breath condensate in volatile or non-volatile form may represent suitable markers. Nasal, bronchial and alveolar NO could be analyzed separately, with implications in the assessment of systemic disease and endothelial dysfunction. Moreover, the profiles of several exhaled gases have a place in phenotyping diabetic patients and their risk of complications. Accordingly, metabolomics of the airway fluid using exhaled breath condensate has recently confirmed the value of this biological matrix for the evaluation of both volatile and non-volatile biomarkers.

Conclusion: Normative studies for reference values are, however, lacking, and the influence of preanalytical variables on the methodology warrants further studies.

Download full-text PDF

Source
http://dx.doi.org/10.1517/17530050903104072DOI Listing

Publication Analysis

Top Keywords

metabolic diseases
12
exhaled breath
12
breath condensate
12
exhaled
9
nitric oxide
8
oxidative stress
8
exhaled gases
8
volatile non-volatile
8
exhaled nitric
4
oxide major
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!