A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

To determine the accuracy of focused assessment with sonography for trauma done by nonradiologists and its comparative analysis with radiologists in emergency department of a level 1 trauma center of India. | LitMetric

Background: Focused assessment with sonography for trauma (FAST) is an important skill during trauma resuscitation. Use of point of care ultrasound among the trauma team working in emergency care settings is lacking in India.

Objective: To determine the accuracy of FAST done by nonradiologists (NR) when compared to radiologists during primary survey of trauma victims in the emergency department of a level 1 trauma center in India.

Materials And Methods: A prospective study was done during primary survey of resuscitation of nonconsecutive patients in the resuscitation bay. The study subjects included NR such as one consultant emergency medicine, two medicine residents, one orthopedic resident and one surgery resident working as trauma team. These subjects underwent training at 3-day workshop on emergency sonography and performed 20 supervised positive and negative scans for free fluid. The FAST scans were first performed by NR and then by radiology residents (RR). The performers were blinded to each other's sonography findings. Computed tomography (CT) and laparotomy findings were used as gold standard whichever was feasible. Results were compared between both the groups. Intraobserver variability among NR and RR were noted.

Results: Out of 150 scans 144 scans were analyzed. Mean age of the patients was 28 [1-70] years. Out of 24 true positive patients 18 underwent CT scan and exploratory laparotomies were done in six patients. Sensitivity of FAST done by NR and RR were 100% and 95.6% and specificity was 97.5% in both groups. Positive predictive value among NR and RR were 88.8%, 88.46% and negative predictive value were 97.5% and 99.15%. Intraobserver performance variation ranged from 87 to 97%.

Conclusion: FAST performed by NRs is accurate during initial trauma resuscitation in the emergency department of a level 1 trauma center in India.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3589858PMC
http://dx.doi.org/10.4103/0974-2700.106324DOI Listing

Publication Analysis

Top Keywords

emergency department
12
department level
12
level trauma
12
trauma center
12
trauma
10
determine accuracy
8
focused assessment
8
assessment sonography
8
sonography trauma
8
center india
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!