Objective: Sentinel lymph node (SLN) scintigraphy is used widespread in breast cancer, but the effect of the radionuclide agent, injection technique, the method of biopsy, tumor localization, breast size remain controversial. We examined the effects of the excisional biopsy in the rate of the SLN identification with lymphoscintigraphy (LS) and intraoperative gamma probe (IGP).
Material And Methods: One hundred patients (age range: 28-79 yr) with breast cancer were included in the study. They consisted of two groups: Group 1; there were 58 patients without excisional biopsy Group 2; there were 42 patients with excisional biopsy LS: 2 hours before the operation, 37 MBq/ ml Tc 99m colloidal rhenium sulphide was injected at the periaerolar region intradermally Anterior and lateral static images were acquired. IGP: The hot spot of greatest radioactivity were marked on the skin during the surgery with IGP and removed. Excised SLNs were examined with frozen section. After that histopathological and immunohistochemical examinations were performed.
Results: SLNs were found in all patients in group 1 (100%), in 39 patients of group 2 (93%) with LS. SLNs were excised in 57 of the 58 patients of group 1 (98%), in 38 of the 42 patients of group 2 (90%) with IGF. Metastases were found in SLNs in 27 patients (28%). Axillary dissection was performed in these patients.
Conclusion: According to results of our study the excisional biopsy was not the only factor but also other factors such as breast mass, calcified or metastatic lymph node may be affected the success rate of the SLN.
Conflict Of Interest: None declared.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3590949 | PMC |
http://dx.doi.org/10.4274/MIRT.28 | DOI Listing |