A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Interstitial biodegradable balloon for reduced rectal dose during prostate radiotherapy: results of a virtual planning investigation based on the pre- and post-implant imaging data of an international multicenter study. | LitMetric

Purpose: To evaluate dose reduction caused by the implantation of an interstitial inflatable and biodegradable balloon device aiming to achieve lower rectal doses with virtual 3D conformal external beam radiation treatment.

Materials And Methods: An inflatable balloon device was placed, interstitially and under transrectal ultrasound guidance, into the rectal-prostate interspace prior treatment initiation of 26 patients with localized prostate cancer, who elected to be treated with radiotherapy (3D CRT or IMRT). The pre- and post-implant CT imaging data of twenty two patients were collected (44 images) for the purpose of the 3D conformal virtual planning presented herein.

Results: The dorsal prostate-ventral rectal wall separation resulted in an average reduction of the rectal V70% by 55.3% (± 16.8%), V80% by 64.0% (± 17.7%), V90% by 72.0% (± 17.1%), and V100% by 82.3% (± 24.1%). In parallel, rectal D2 ml and D0.1 ml were reduced by 15.8% (± 11.4%) and 3.9% (± 6.4%), respectively.

Conclusions: Insertion of the biodegradable balloon into the prostate-rectum interspace is similar to other published invasive procedures. In this virtual dose distribution analysis, the balloon insertion resulted in a remarkable reduction of rectal volume exposed to high radiation doses. This effect has the potential to keep the rectal dose lower especially when higher than usual prostate dose escalation protocols or hypo-fractionated regimes are used. Further prospective clinical investigations on larger cohorts and more conformal radiation techniques will be necessary to define the clinical advantage of the biodegradable interstitial tissue separation device.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radonc.2013.01.007DOI Listing

Publication Analysis

Top Keywords

biodegradable balloon
12
rectal dose
8
virtual planning
8
pre- post-implant
8
post-implant imaging
8
imaging data
8
balloon device
8
reduction rectal
8
rectal
7
balloon
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!