A sensitive and high-throughput LC-MS/MS method has been developed and validated for the combined determination of esomeprazole and naproxen in human plasma with ibuprofen as internal standard. Solid-phase extraction was used to extract both analytes and internal standard from human plasma. Chromatographic separation was achieved in 4.0 min on XBridge C18 column using acetonitrile-25 mM ammonium formate (70:30, v/v) as mobile phase. Mass detection was achieved by ESI/MS/MS in negative ion mode, monitoring at m/z 344.19 → 194.12, 229.12 → 169.05 and 205.13 → 161.07 for esomeprazole, naproxen and IS, respectively. The calibration curves were linear from 3.00 to 700.02 ng/mL for esomeprazole and 0.50 to 150.08 ng/mL for naproxen. The intra- and inter-batch precision and accuracy across four quality control levels met established criteria of US Food and Drug Administration guidelines. The assay is suitable for measuring accurate esomeprazole and naproxen plasma concentrations in human bioequivalence study following combined administration.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.2878DOI Listing

Publication Analysis

Top Keywords

esomeprazole naproxen
16
human plasma
12
sensitive high-throughput
8
high-throughput lc-ms/ms
8
lc-ms/ms method
8
determination esomeprazole
8
naproxen human
8
internal standard
8
esomeprazole
5
naproxen
5

Similar Publications

A man in his 60s presented with a widespread erythematous rash and associated chills, paraesthesia and haematuria. He had recently commenced naproxen/esomeprazole. Blood tests showed hypereosinophilia (0.

View Article and Find Full Text PDF

After performing liquid-liquid extraction with ethyl acetate and HCl, samples from 12 volunteers who performed sequential collections after taking a tablet of naproxen alone (n = 6) or associated with esomeprazole (n = 6) were analyzed in a triple quadrupole mass spectrometer 8040 LC MS/MS Shimadzu. Separation of naproxen and its main metabolite 6-O-desmethylnaproxen was performed in a Shim-Pack XR-ODS 75Lx2.0 column and C18 pre-column at 40°C using a mixture of methanol and ammonium acetate 10 mM (70:30, v/v) with an injection rate of 0.

View Article and Find Full Text PDF

A novel, validated, reversed-phase (RP), chiral high performance liquid chromatography (HPLC) method was developed for the enantiopurity control analysis of naproxen, a frequently used non-steroidal anti-inflammatory agent using polysaccharide-type chiral stationary phase (CSP). In the screening phase of method development, seven columns were tested in polar organic (PO) mode using mobile phases consisting of 0.1% acetic acid in methanol, ethanol, 2-propanol, and acetonitrile.

View Article and Find Full Text PDF

Background And Objective: Bioequivalence tests are fundamental step in assessing the equivalence in bioavailability between a test and reference product. In practice, two separate linear mixed models (LMMs) with random subject effects, which have an area under the concentration-time curve (AUC) and the peak concentration (C) as the responses, have become the gold standard for evaluating bioequivalence. Recently, Lee et al developed a multivariate hierarchical generalized linear model (HGLM) for several responses that modeled correlations among multivariate responses via correlated random effects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!