Objective: To investigate the two-body wear performance of monolithic dental ceramics with different surface treatments.
Method And Materials: Standardized specimens (n = 8/ series) were fabricated from three monolithic dental ceramics (experimental translucent zirconia, experimental shaded zirconia, lithium disilicate). Four groups of each material were defined according to clinically relevant surface treatments: polished, polishedground, polished-ground-repolished, glazed. Two-body wear tests with steatite antagonists were performed in a chewing simulator. Surface roughness (R(a)) was controlled, and wear depths of specimens and antagonistic wear areas were calculated in relation to human enamel as reference. Statistical analysis of wear data was carried out using one-way ANOVA and Bonferroni multiple comparison test for post hoc analysis (α = .05). Scanning electron microscopy was applied for evaluating wear performance of ceramics and antagonists.
Results: Polished, ground, and repolished zirconia showed no wear, while glaze was abraded. Irrespective of the surface treatment, wear depth of lithium disilicate was significantly (P = .001) higher than for zirconia but only about half as high as for the enamel reference (274.14 µm). Mean relative wear areas of steatite antagonists (enamel reference: 1.25 mm2) ranged between 0.86 and 1.57 for zirconia, and between 1.79 and 2.28 for lithium disilicate, with the highest values found after grinding and glazing. Steatite surfaces were smooth when opposed to polished/ground/repolished zirconia, and ploughed when opposed to glaze and lithium disilicate.
Conclusion: Translucent and shaded experimental zirconia yielded superior wear behavior and lower antagonistic wear compared to lithium disilicate. A trend to higher ceramic and antagonistic wear was shown after grinding and glazing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3290/j.qi.a29151 | DOI Listing |
Arch Bone Jt Surg
January 2024
Orthopedic Research Center, Department of Orthopedic Surgery, Mashhad University of Medical sciences, Mashhad, Iran.
Second-generation large-diameter head hip resurfacing (HR) arthroplasty has gained popularity in terms of its potential for minimal wear and the preservation of proximal femoral bone stock. HR faces challenges, such as increased hip fracture rates and adverse reactions to metal detritus, despite the fact that over one million metal-on-metal (MoM) arthroplasties have been performed globally. FDA issued warnings in 2011 and 2016 regarding higher failure rates in women and categorized MoM implants as high-risk, influencing U.
View Article and Find Full Text PDFHeliyon
January 2025
University of Coimbra, CEMMPRE, ARISE, Department of Mechanical Engineering, Rua Luís Reis Santos, 3030-788, Coimbra, Portugal.
Recent advancements in aerospace industry demand intricate aero-engine parts, leading to the increased use of titanium alloys, particularly Ti-17, due to its high strength, thermal stability, and corrosion resistance. However, its low thermal conductivity and tool wear tendency pose significant machining challenges, impacting surface integrity, fatigue life, and overall component performance. This study investigates the Wire Electrical Discharge Cutting (WEDC) process, revealing that the mechanism behind improved surface integrity lies in the controlled thermal input, which minimizes phase transformations and reduces residual stresses.
View Article and Find Full Text PDFEar Hear
January 2025
Department of Psychological Sciences, Kansas State University, Manhattan, KS, USA.
Objectives: Occupational hearing loss is a significant problem worldwide despite the fact that it can be mitigated by the wearing of hearing protection devices (HPDs). When surveyed, workers frequently report that worsened work performance while wearing HPDs is one reason why they choose not to wear them. However, there have been few studies to supplement these subjective reports with objective measures.
View Article and Find Full Text PDFUltrasonics
January 2025
State Key Laboratory of Intelligent Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China.
Steel precision matching parts are widely used in aerospace and automobiles. In order to ensure the stability of the system, the matching parts' mating surfaces, such as inner holes and outer shafts, are required to achieve nano-surface roughness and submicron-shape accuracy. Diamond-cutting technology is generally used for ultra-precision machining processes.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Department of Orthopedic, Taizhou Hospital of Zhejiang Province Affiliated to Wenzhou Medical University, Taizhou, Zhejiang, China.
Knee arthritis is a common degenerative joint disease, usually with joint swelling, chronic pain, and dysfunction as the main clinical manifestations. At present, the conservative treatment for knee arthritis is mostly using anti-inflammatory and analgesic drugs, but the effect is mostly temporary, and can not prevent its progress and surgery is usually the last treatment method. Total knee arthroplasty, also known as TKA, is one of the most effective treatments for osteoarthritis of the knee that has progressed to the end stage.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!