We demonstrate motion-free beam quality M² measurements of stigmatic, simple astigmatic, and general astigmatic (twisted) beams using only a focus-tunable liquid lens and a CCD camera. We extend the variable-focus technique to the characterization of general astigmatic beams by measuring the 10 second-order moments of the power density distribution for the twisted beam produced by passage through multimode optical fiber. Our method measures the same M² values as the traditional variable-distance method for a wide range of laser beam sources, including nearly TEM(00) (M²≈1) and general astigmatic multimode beams (M²≈8). The method is simple and compact, with no moving parts or complex apparatus and measurement precision comparable to the standard variable-distance method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.52.001591 | DOI Listing |
Cesk Slov Oftalmol
December 2024
Objective: The aim of this study is to compare the results of preoperative biometric data measured with optical biometers of different generations in patients with cataract. Lenstar optical biometry is based on the principle of optical low-coherence reflectometry (OLCR), and Anterion on swept-source optical coherence tomography (SS-OCT).
Material And Methods: A total of 200 eyes (103 patients) were included in a prospective study at the Faculty Hospital in Trenčín the period from June 2023 to January 2024.
Cureus
November 2024
General Physician, AlJaber Eye and ENT Hospital, Al-Ahsa, SAU.
Corneal curvature (CC) is a crucial ocular optical system parameter, indicating the shape of the cornea expressed in radii. This study aims to investigate the relationship between CC, age, gender, refractive errors, and central corneal thickness (CCT) in Saudi Arabia, a field lacking in research. Data were gathered from Imam Medical Center in Riyadh and Dr.
View Article and Find Full Text PDFEye Contact Lens
December 2024
Cornea and Laser Eye Institute-CLEI Center for Keratoconus (J.D.G., B.S., T.P., C.E., P.S.H., S.A.G.), Teaneck, NJ; Department of Ophthalmology (J.D.G., D.K., P.S.H., S.A.G.), Rutgers-New Jersey Medical School, Newark, NJ; TX; OVITZ Corporation (N.B., J.W.), Rochester, NY; College of Optometry (G.Y.), University of Houston, Houston, TX.
Purpose: To report interim results of a single center, randomized, double-blind, crossover-controlled clinical trial comparing wavefront-guided (wfg) scleral lenses (SLs) to traditional scleral lenses (tSLs) for patients with a history of irregular corneal astigmatism (ICA).
Methods: Thirty-one ICA eyes of 18 participants were reviewed, 23 with keratoconus, six postcorneal refractive ectasia, and two postpenetrating keratoplasty. Patients with corneal or lens opacities were not excluded from participating.
Purpose: To evaluate the visual outcomes of keratorefractive lenticule extraction using a new version of a femtosecond laser platform with semi-automated cyclotorsion compensation in comparison to the previous generation without cyclotorsion control.
Methods: This was an ambispective study of consecutive eyes treated by SMILE with the VisuMax and VISUMAX 800 femtosecond lasers at the Uma Eye clinic, Chennai, India between June 2022 and July 2023. Inclusion criteria were myopia up to -10 D and astigmatism between 1.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!