Background: After promising results were obtained from studies in large animals, a technique using indocyanine green (ICG) is being introduced for sentinel lymph node (SLN) biopsy in colon cancer patients.

Subjects And Methods: Colon cancer patients without clinical signs of metastatic disease, presenting at the VU University Medical Center (Amsterdam, The Netherlands) or Kennemer Gasthuis (Haarlem, The Netherlands), were asked to participate in the study. During laparoscopy, a subserosal injection of 2.5 mg of ICG diluted in 1 mL of 0.9% NaCl plus 2% human albumin was performed using a percutaneously inserted long rigid or flexible needle. After injection, a near-infrared laparoscope (Olympus Corp., Tokyo, Japan) was used for lymph flow and SLN visualization. The SLNs were laparoscopically harvested and analyzed by a senior pathologist using multisectioning and immunohistochemistry.

Results: Fourteen patients were included (six women, eight men), with a median age of 75.5 (interquartile range [IQR], 67.8-81.0) years and a median body mass index of 25.1 (IQR, 22.7-26.0) kg/m(2). Median tumor diameter was 4.5 (IQR, 3.4-7.0) cm. At least one SLN was identified in all patients, with a median number of 2.0 (IQR, 2.0-3.3) SLNs. The median time between injection and identification of the SLN was 15.0 (IQR, 13.3-29.3) minutes. Positioning of the needle tip into the subserosal layer was found to be more effective using the flexible needle. When this flexible needle was used, less spill of dye was observed. All SLNs were negative. We observed four false-negative nodes, all after using a rigid needle. None of the patients showed an adverse reaction to the ICG injection.

Conclusions: Preliminary results of laparoscopic sentinel node identification using a near-infrared dye show this procedure is safe and feasible. It was possible to detect lymph nodes in all patients. Large tumor size, drainage to adjacent lymphatic vessels, and the use of a rigid needle might contribute to false-negative nodes.

Download full-text PDF

Source
http://dx.doi.org/10.1089/lap.2012.0407DOI Listing

Publication Analysis

Top Keywords

flexible needle
12
laparoscopic sentinel
8
sentinel lymph
8
lymph node
8
node identification
8
near-infrared dye
8
colon cancer
8
false-negative nodes
8
rigid needle
8
patients
6

Similar Publications

Quality-by-design principles applied to the development and optimisation of lidocaine-loaded dissolving microneedle arrays - a proof-of-concept.

Drug Deliv Transl Res

January 2025

Leicester Institute of Pharmaceutical, Health and Social Care Innovations, Leicester School of Pharmacy, De Montfort University, Leicester, LE1 9BH, UK.

The use of dissolving microneedle arrays (dMNA) for intradermal and transdermal drug delivery has been a growing trend in the field for the past decades. However, a lack of specific regulatory standards still hinders their clinical development and translation to market. It is also well-known that dMNA composition significantly impacts their performance, with each new formulation potentially presenting a challenge for developers, manufacturers and regulatory agencies.

View Article and Find Full Text PDF

Rapid and accurate molecular diagnostics are crucial for preventing the global spread of emerging infectious diseases. However, the current gold standard for nucleic acid detection, reverse transcription polymerase chain reaction (RT-PCR), relies heavily on traditional magnetic beads or silica membranes for nucleic acid extraction, resulting in several limitations, including time-consuming processes, the need for trained personnel, and complex equipment. Therefore, there is an urgent need for fully integrated nucleic acid detection technologies that are simple to operate, rapid, and highly sensitive to meet unmet clinical needs.

View Article and Find Full Text PDF

Background: Low-frequency acupuncture is used to maintain skeletal muscle flexibility and improve joint range of motion; however, its definite effects are unclear. This study aimed to determine the effects of low-frequency acupuncture on muscle and fascial stiffness and ankle dorsiflexion range of motion.

Methods: The participants included 12 randomly selected healthy adults.

View Article and Find Full Text PDF

Foreign body (FB) aspiration in children is a common emergency. Traditionally, rigid bronchoscopy has been considered to be the mainstay for removal. However, in certain cases, flexible bronchoscopy can prove to be a better option and avoid thoracic surgery and unnecessary morbidity.

View Article and Find Full Text PDF

The incidence of asymptomatic thyroid nodules has risen enormously, with > 90% being benign. Despite limited long-term data, significant nodule growth (SNG) is common. Guidelines recommend cytology reevaluation if SNG occurs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!