A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Bioluminescent detection of peroxynitrite with a boronic acid-caged luciferin. | LitMetric

Bioluminescent detection of peroxynitrite with a boronic acid-caged luciferin.

Free Radic Biol Med

Department of Pharmacology, University of Illinois at Chicago, Chicago, IL 60612, USA; Section of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL 60612, USA. Electronic address:

Published: August 2013

Peroxynitrite, a highly reactive biological oxidant, is formed under pathophysiologic conditions from the diffusion-limited reaction of nitric oxide and superoxide radical anion. Peroxynitrite has been implicated as the mediator of nitric oxide toxicity in many diseases and as an important signaling disrupting molecule (L. Liaudet et al., Front. Biosci.14, 4809-4814, 2009) [1]. Biosensors effective at capturing peroxynitrite in a specific and fast enough manner for detection, along with readouts compatible with in vivo studies, are lacking. Here we report that the boronic acid-based bioluminescent system PCL-1 (peroxy-caged luciferin-1), previously reported as a chemoselective sensor for hydrogen peroxide (G.C. Van de Bittner et al., Proc. Natl. Acad. Sci. USA107, 21316-21321, 2010) [2], reacts with peroxynitrite stoichiometrically with a rate constant of 9.8±0.3×10(5)M(-1)s(-1) and a bioluminescence detection limit of 16nM, compared to values of 1.2±0.3M(-1)s(-1) and 231nM for hydrogen peroxide. Further, we demonstrate bioluminescent detection of peroxynitrite in the presence of physiological competitors: carbon dioxide, glutathione, albumin, and catalase. We also demonstrate the utility of this method to assess peroxynitrite formation in mammalian cells by measuring peroxynitrite generated under normal culture conditions after stimulation of macrophages with bacterial endotoxin lipopolysaccharide. Thus, the PCL-1 method for measuring peroxynitrite generation shows superior selectivity over other oxidants under in vivo conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3795912PMC
http://dx.doi.org/10.1016/j.freeradbiomed.2013.02.020DOI Listing

Publication Analysis

Top Keywords

peroxynitrite
9
bioluminescent detection
8
detection peroxynitrite
8
nitric oxide
8
hydrogen peroxide
8
measuring peroxynitrite
8
peroxynitrite boronic
4
boronic acid-caged
4
acid-caged luciferin
4
luciferin peroxynitrite
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!