The purpose of this study was to evaluate the applicator-guided volumetric-modulated arc therapy (AGVMAT) solution as an alternative to high-dose-rate brachytherapy (HDR-BRT) treatment of the vaginal vault in patients with gynecological cancer (GC). AGVMAT plans for 51 women were developed. The volumetric scans used for plans were obtained with an implanted CT-compatible vaginal cylinder which provides spatial registration and immobilization of the gynecologic organs. Dosimetric and radiobiological comparisons for planning target volume (PTV) and organs at risk (OARs) were performed by means of a dose-volume histogram (DVH), equivalent uniform dose (EUD), and local tumor control probability (LTCP). In addition, the integral dose and the overall delivery time, were evaluated. The HDR-BRT averages of EUD and minimum LTCP were significantly higher than those of AGVMAT. Doses for the OARs were comparable for the bladder and sigmoid, while, although HDR-BRT was able to better spare the bowel, AGVMAT provided a significant reduction of d2cc, d1cc, and dmax (p < 0.01) for the rectum. AGVMAT integral doses were higher than HDR-BRT with low values in both cases. Delivery times were about two or three times higher for HDR-BRT with respect to the single arc technique (AGVMAT1) and dual arc technique (AGVMAT2), respectively. The applicator-guided volumetric-modulated arc therapy seems to have the potential of improving rectum avoidance. However, brachytherapy improves performance in terms of PTV coverage, as demonstrated by a greater EUD and better LTCP curves.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5714358PMC
http://dx.doi.org/10.1120/jacmp.v14i2.4075DOI Listing

Publication Analysis

Top Keywords

applicator-guided volumetric-modulated
12
volumetric-modulated arc
12
arc therapy
12
local tumor
8
tumor control
8
control probability
8
evaluate applicator-guided
8
solution alternative
8
treatment vaginal
8
vaginal vault
8

Similar Publications

We performed this dosimetric study to compare a nonstandard volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) techniques with high-dose rate (HDR) brachytherapy (BRT) plan of vaginal vault in patients with postoperative endometrial cancer (EC). Twelve postoperative patients with early stage EC were included in this study. Three plans were performed for each patient; dosimetric and radiobiological comparisons were made using dose-volume histograms and equivalent dose for determining the planning target volume (PTV) coverages in brachytherapy and external beam radiotherapy, and organs-at-risk (OARs) doses between three different delivery techniques.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the applicator-guided volumetric-modulated arc therapy (AGVMAT) solution as an alternative to high-dose-rate brachytherapy (HDR-BRT) treatment of the vaginal vault in patients with gynecological cancer (GC). AGVMAT plans for 51 women were developed. The volumetric scans used for plans were obtained with an implanted CT-compatible vaginal cylinder which provides spatial registration and immobilization of the gynecologic organs.

View Article and Find Full Text PDF

The aim of this study was to report the feasibility of volumetric-modulated arc therapy (VMAT) in the postoperative irradiation of the vaginal vault. Moreover, the VMAT technique was compared with 3D conformal radiotherapy (3D-CRT) and fixed-field intensity-modulated radiotherapy (IMRT), in terms of target coverage and organs at risk sparing. The number of monitor units and the delivery time were analyzed to score the treatment efficiency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!