Background: There is a relative paucity of data linking inappropriate implantable cardioverter-defibrillator (ICD) shocks to adverse clinical outcomes.

Objective: To examine the association between inappropriate ICD shocks and mortality or heart transplantation in a large population cohort.

Design, Setting, Patients: A cohort study which included all subjects who underwent ICD implantation between 1998 and 2008 and were followed up at our institution.

Main Outcome Measures: Multivariable Cox regression analyses were conducted to investigate the effect of inappropriate shocks on the risk of death and heart transplantation. Appropriate and inappropriate ICD therapies were modelled as time-dependent covariates.

Results: A total of 1698 patients were included. During a median follow-up of 30 months, there were 246 (14.5%) deaths and 42 (2.5%) heart transplants. The incidence of inappropriate shocks was 10% at 1 year and 14% at 2 years. In the adjusted model, inappropriate shocks were not associated with death or transplantation (HR=0.97, 95% CI 0.70 to 1.36, p value=0.873). In contrast, appropriate shocks were associated with adverse outcomes (HR=3.11, 95% CI 2.41 to 4.02, p value<0.001). The lack of association between inappropriate shocks and outcomes persisted for those with severely impaired left ventricular function (ejection fraction <30%) and for those receiving multiple inappropriate treatments.

Conclusions: In this study, we observed no association between inappropriate ICD shocks and increased mortality or heart transplantation, even among those with severely impaired cardiac function. These findings question whether inappropriate ICD shocks lead to adverse outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1136/heartjnl-2012-303407DOI Listing

Publication Analysis

Top Keywords

inappropriate shocks
12
icd shocks
8
inappropriate icd
8
heart transplantation
8
shocks associated
8
inappropriate
7
shocks
7
prognostic impact
4
impact inappropriate
4
inappropriate defibrillator
4

Similar Publications

Background: Treatment with implantable cardioverter-defibrillators (ICDs) effectively prevents sudden cardiac death (SCD) in patients with hypertrophic cardiomyopathy (HCM). Identifying patients most likely to benefit from a primary prevention ICD remains challenging. We aimed to investigate the long-term incidence of ICD therapy in patients with HCM according to SCD-risk at baseline.

View Article and Find Full Text PDF

Critical analysis of electrograms of any therapy delivery event is paramount to identify the etiology, specificity, and sensitivity of the programmed algorithms to differentiate supraventricular versus ventricular tachycardia, its effectiveness, and potential interventions to prevent recurrence. Besides the aspects mentioned above, this case delves into the potential limitations of existing algorithms and the adverse effects of anti-tachycardia pacing.

View Article and Find Full Text PDF

[Remote monitoring for patients with cardiac implantable electronic devices and heart failure].

Herzschrittmacherther Elektrophysiol

January 2025

Hannover Herzrhythmus Centrum, Klinik für Kardiologie und Angiologie, Medizinische Hochschule Hannover, Carl-Neuberg-Str. 1, 30625, Hannover, Deutschland.

The digitalization in healthcare facilitates continuous monitoring of relevant medical parameters through internal and external sensors. For patients with heart failure and cardiac implantable electronic devices (CIEDs), telemedicine has the potential to improve patient care and reduce use of healthcare resources. Remote monitoring shortens the response time to a clinical event, reduces inappropriate shocks, and increases patient satisfaction.

View Article and Find Full Text PDF

Background: Cardiogenic shock (CS) is a heterogeneous clinical syndrome, making it challenging to predict patient trajectory and response to treatment. This study aims to identify biological/molecular CS subphenotypes, evaluate their association with outcome, and explore their impact on heterogeneity of treatment effect (ShockCO-OP, NCT06376318).

Methods: We used unsupervised clustering to integrate plasma biomarker data from two prospective cohorts of CS patients: CardShock (N = 205 [2010-2012, NCT01374867]) and the French and European Outcome reGistry in Intensive Care Units (FROG-ICU) (N = 228 [2011-2013, NCT01367093]) to determine the optimal number of classes.

View Article and Find Full Text PDF

False Alarms in Wearable Cardioverter Defibrillators-A Relevant Issue or an Insignificant Observation.

J Clin Med

December 2024

Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany.

The wearable cardioverter defibrillator (WCD) has emerged as a valuable tool used for temporary protection from sudden cardiac death. However, since the WCD uses surface electrodes to detect arrhythmias, it is susceptible to inappropriate detection. Although shock conversion rates for the WCD are reported to be high for detected events, its efficacy in clinical practice tends to be degraded by patient noncompliance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!