Electrical muscle stimulation demonstrates potential for restoring functional movement and preventing muscle atrophy after spinal cord injury (SCI). Control systems used to optimize delivery of electrical stimulation protocols depend upon mathematical models of paralyzed muscle force outputs. While accurate, the Hill-Huxley-type model is very complex, making it difficult to implement for real-time control. As an alternative, we propose a modified Wiener-Hammerstein system to model the paralyzed skeletal muscle dynamics under electrical stimulus conditions. Experimental data from the soleus muscles of individuals with SCI was used to quantify the model performance. It is shown that the proposed Wiener-Hammerstein system is at least comparable to the Hill-Huxley-type model. On the other hand, the proposed system involves a much smaller number of unknown coefficients. This has substantial advantages in identification algorithm analysis and implementation including computational complexity, convergence and also in real time model implementation for control purposes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3586551 | PMC |
http://dx.doi.org/10.1016/j.automatica.2008.09.023 | DOI Listing |
ISA Trans
July 2024
School of Electrical and Information Engineering, Zhengzhou University of Light Industry, Zhengzhou 450002, PR China.
In this study, a novel estimation scheme is proposed for identifying extended Wiener-Hammerstein systems with hysteresis nonlinearity subject to quantised measurements. The proposed scheme is established in a self-error learning framework to achieve high-performance parameter estimation compared with classic error feedback learning estimation algorithms. Initially, the useful identification data can be extracted from contaminated system data by introducing an adaptive filter.
View Article and Find Full Text PDFSensors (Basel)
February 2022
Institute of Telecommunications, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw, Poland.
Visible Light Communications (VLC) have gained much popularity lately. In such a system, a white LED (Light-Emitting Diode) plays a double role as a light source and a transmitter. The main problem here is that the LED exhibits a low bandwidth and high nonlinearity, so the equalization of the LED nonlinear dynamic response is necessary.
View Article and Find Full Text PDFRev Sci Instrum
March 2021
Chair for Medical Engineering, Ruhr University Bochum, 44801 Bochum, Germany.
When identifying nonlinear systems with input-output measurements, a suitable test signal must be selected. Nonlinear systems are almost always in a cascade with linear systems, i.e.
View Article and Find Full Text PDFISA Trans
September 2018
School of Automation, Beijing Institute of Technology, Beijing, China. Electronic address:
This paper investigates parameter identification of nonlinear Wiener-Hammerstein systems by using filter gain and novel cost function. Taking into account the system information is corrupted by noise, the filter gain is exploited to extract the system data. By using several auxiliary filtered variables, an extended estimation error vector is developed.
View Article and Find Full Text PDFComput Biol Med
November 2013
Measurement and Control Engineering Research Center, Idaho State University, Pocatello, ID 83209, USA. Electronic address:
Estimating skeletal muscle (finger) forces using surface Electromyography (sEMG) signals poses many challenges. In general, the sEMG measurements are based on single sensor data. In this paper, two novel hybrid fusion techniques for estimating the skeletal muscle force from the sEMG array sensors are proposed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!