Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Electrical isolation of pulmonary vein (PV) conduction from the left atrium (LA) is the cornerstone of successful atrial fibrillation (AF) ablation. Exit block is confirmed by the absence of LA capture during pacing from a circular mapping catheter positioned in the PV; however, far-field capture of the left atrial appendage (LAA) (pseudo-pulmonary vein exit conduction) can occur. In this study, we evaluated a methodology for identifying pseudo-exit conduction.
Methods And Results: A total of 135 consecutive AF patients undergoing PV isolation were studied. After circumferential ablation established PV entrance block, circumferential pacing (10 mA at 2.0 msec) was performed to assess exit block. In 16 (11.9%) patients, pacing the anterior poles of the left superior PV (LSPV) captured the LA. To differentiate true PV exit conduction from pseudo-exit conduction, the ablation catheter was positioned within the LAA during PV pacing. LAA activation preceding PV capture was consistent with far-field capture and this was confirmed by demonstrating local capture and exit block with decreasing pacing output. Using this approach, 14 patients (10.4%) were identified with pseudo-exit conduction.
Conclusions: Due to the close proximity between the LSPV and LAA, pseudo-exit conduction is not uncommon and may lead to the erroneous conclusion that the LSPV is not isolated. Using this method to differentiate pseudo-exit conduction from true exit conduction should prevent unnecessary ablation after achievement of complete PV isolation.