A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Energy efficiency monitoring--which sensors are really needed? | LitMetric

Plant balancing of waste-to-energy plants is a key issue in determining plant performance and operating efficiency. Traditionally, plant efficiency is determined only during the acceptance test by the means of an ex-post energy balance. For continuous operation, energy efficiency is estimated on a monthly or yearly basis using the waste throughput and average lower heating value. At Afval Energie Bedrijf in Amsterdam efficiency has to be reported on a monthly basis. Measured data from 83 positions is required to obtain the efficiency of the Hoog Rendement Central block with an ex-post energy balance on a continuous basis. This study investigated the importance of the different sensors. Efficiency calculations were performed after discarding the less important measuring positions. The measured data was replaced by the design value in the calculation. The total average margin of error per year for the efficiency value was found to be only 0.1% when the 23 most significant (instead of 83) measuring points were used, whereas individual values may differ by less than 0.5%. Operators of plants with fewer sensors can monitor their efficiency continuously if they know the most important positions.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0734242X13477720DOI Listing

Publication Analysis

Top Keywords

energy efficiency
8
efficiency
8
ex-post energy
8
energy balance
8
balance continuous
8
measured data
8
energy
4
efficiency monitoring--which
4
monitoring--which sensors
4
sensors needed?
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!