Reconstruction of a bony bankart lesion: best fit based on radius of curvature.

Am J Sports Med

Department of Orthopaedics and Rehabilitation, Oregon Health and Science University, 3181 Southwest Sam Jackson Park Road, Portland, OR 97239-3098, USA.

Published: May 2013

Background: The inferior coracoid process has traditionally been considered to be the gold standard for glenoid augmentation after anteroinferior bone loss. Other autograft sites, and more recently, osteochondral allograft sites, have been described as potential donor sources.

Purpose: Potential autograft and osteochondral allograft sites were compared to identify the graft source that would provide the best fit for glenoid augmentation.

Study Design: Controlled laboratory study.

Methods: Mose circles, a geometric tool found on a standard goniometer, were used to make radius of curvature measurements of 10 anatomic locations in 17 cadaveric specimens. The bony surface of the glenoid, measured from superior to inferior (G-SI) and from anterior to posterior (G-AP), was used as the standard for comparison. Autograft sites were the inferior coracoid, lateral coracoid, and inner table of the iliac crest. Potential osteochondral allograft sites were the radial head, scaphoid fossa of the distal radius (S-DR), lunate fossa of the distal radius (L-DR), medial tibial plateau, and lateral distal tibia. An acceptable match for autograft sites was based on a paired analysis and defined as a radius of curvature within 5 mm of the G-SI or the G-AP of the same cadaveric specimen. Allograft sites were evaluated using an unpaired analysis in which an ideal fit was defined as a radius of curvature of 25 to 30 mm, based on the interquartile range of the G-SI and G-AP.

Results: The median (interquartile range) radii of curvature for the G-SI and G-AP were 30 mm (range, 25-30 mm) and 25 mm (range, 25-25 mm), respectively. The inferior coracoid was within 5 mm of the G-SI 59% of the time and the G-AP 94% of the time; no measurements from the lateral coracoid or iliac crest were within the range of the glenoid radius of curvature. Analysis of the allograft sites demonstrated an acceptable fit for 94% of the distal tibia, 68% of the medial tibial plateau, 12% of the S-DR, and 0% of the L-DR and the radial head specimens.

Conclusion: An autograft of the inferior coracoid or an osteochondral allograft of the lateral distal tibia provided the best match to re-establish the native radius of curvature of the glenoid.

Clinical Relevance: To best re-create the native glenohumeral anatomy, surgeons should consider the use of an autograft of the inferior coracoid or an osteochondral allograft of the lateral distal tibia for the reconstruction of osseous glenoid defects.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0363546513478578DOI Listing

Publication Analysis

Top Keywords

radius curvature
24
inferior coracoid
20
osteochondral allograft
20
allograft sites
20
distal tibia
16
autograft sites
12
lateral distal
12
best fit
8
radius
8
sites
8

Similar Publications

Additively Manufactured Flexible EGaIn Sensor for Dynamic Detection and Sensing on Ultra-Curved Surfaces.

Sensors (Basel)

December 2024

Sauvage Laboratory for Smart Materials, Shenzhen Key Laboratory of Flexible Printed Electronics Technology, Harbin Institute of Technology, Shenzhen 518055, China.

Electronic skin is widely employed in multiple applications such as health monitoring, robot tactile perception, and bionic prosthetics. In this study, we fabricated millimeter-scale electronic skin featuring compact sensing units using the Boston Micro Fabrication S130 (a high-precision additive manufacturing device) and the template removal method. We used a gallium-based liquid metal and achieved an inner channel diameter of 0.

View Article and Find Full Text PDF

Improved S-bend optical waveguide loss formula verified by experiments.

Sci Rep

January 2025

Department of Electrical Engineering, Faculty of Science and Technology, University Al Azhar Indonesia, Jakarta, Indonesia.

Curvature of a dielectric waveguide always leads to attenuation of the mode power as it propagates through the curved region. In single mode guides, bending loss becomes significant as the radius of curvature reduces and is strongly dependent on the confinement of the guided mode, so that weakly guiding waveguides can tolerate only large radii of curvature. In this paper we verify our new theoretical version on power loss prediction of S-bend optical waveguides by using analytical theory based on integration of absorption coefficient and compare it to the experimental measurement of such waveguide bends.

View Article and Find Full Text PDF

Background: The increasing prevalence of myopia among Chinese children and adolescents, especially at younger ages, has emerged as a significant concern in recent years. Pre-myopia is a key period for myopia prevention and control in children and adolescents. Previous studies suggested auricular acupressure (AA) therapy might offer a viable approach to prevent and slow down myopia progression.

View Article and Find Full Text PDF

Over the past 30 years, researchers have developed X-ray-focusing telescopes by employing the principle of total reflection in thin metal films. The Wolter-I focusing mirror with variable-curvature surfaces demands high precision. However, there has been limited investigation into the removal mechanisms for variable-curvature X-ray mandrels, which are crucial for achieving the desired surface roughness and form accuracy, especially in reducing mid-spatial frequency (MSF) errors.

View Article and Find Full Text PDF

Compartmental analysis of retinal vascular parameters and thickness in myopic eyes using SS-OCTA.

Front Med (Lausanne)

December 2024

Chongqing Key Laboratory of Prevention and Treatment on Major Blinding Diseases, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.

Article Synopsis
  • The study examined how myopia affects the thickness and structure of retinal blood vessels using advanced imaging technology in 100 participants.
  • The findings revealed that individuals with high myopia had significantly lower vessel density and thinner retinal layers, particularly noticeable in the superficial and nerve fiber layers.
  • There was a noted correlation between certain ocular parameters, such as axial length to curvature radius ratio, and retinal thickness in non-high myopic eyes, while high myopic eyes showed less correlation in these aspects.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!