We present a low noise single-frequency and single-polarization distributed Bragg reflector fiber laser at 1083 nm by using a 1.8 cm long newly developed ytterbium-doped phosphate single mode glass fiber. The maximum output power is more than 100 mW with a slope efficiency of >29.6%. The signal to noise ratio is higher than 61 dB and the laser linewidth of less than 2 kHz is estimated. The obtained relative intensity noise for frequencies of over 4.0 MHz is less than -150 dB/Hz, which approaches the shot noise limit. The achieved linear polarization extinction ratio is more than 30 dB.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OL.38.000501 | DOI Listing |
Neuroinformatics
January 2025
Department of Information Technology, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Ramapuram, Chennai, 600089, India.
Brain tumours are one of the most deadly and noticeable types of cancer, affecting both children and adults. One of the major drawbacks in brain tumour identification is the late diagnosis and high cost of brain tumour-detecting devices. Most existing approaches use ML algorithms to address problems, but they have drawbacks such as low accuracy, high loss, and high computing cost.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
School of Physics, Beihang University, Beijing 100191, China.
Exploiting biomimetic perception of invisible spectra in flexible artificial human vision systems (HVSs) is crucial for real-time dynamic information processing. Nevertheless, the fast processing of motion objects in natural environments poses a challenge, necessitating that these artificial HVSs simultaneously have swift photoresponse and nonvolatile memory. Here, inspired by the human retina, we propose a flexible UV neuromorphic visual synaptic device (NeuVSD) based on GaO@GaN-composited nanowires for dynamic visual perception.
View Article and Find Full Text PDFHemasphere
January 2025
Department of Internal Medicine, Hematology and Oncology, and Institute of Medical Genetics and Genomics, University Hospital Brno and Medical Faculty Masaryk University Brno Czech Republic.
In chronic lymphocytic leukemia, the reliability of next-generation sequencing (NGS) to detect variants ≤10% allelic frequency (low-VAF) is debated. We tested the ability to detect 23 such variants in 41 different laboratories using their NGS method of choice. The sensitivity was 85.
View Article and Find Full Text PDFFront Neurorobot
January 2025
Software Engineering College, Zhengzhou University of Light Industry, Zhengzhou, China.
Introduction: Tracking the hidden states of dynamic systems is a fundamental task in signal processing. Recursive Kalman Filters (KF) are widely regarded as an efficient solution for linear and Gaussian systems, offering low computational complexity. However, real-world applications often involve non-linear dynamics, making it challenging for traditional Kalman Filters to achieve accurate state estimation.
View Article and Find Full Text PDFFront Neurosci
January 2025
School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan City, China.
Introduction: Transcranial magnetic stimulation (TMS) is widely used for the noninvasive activation of neurons in the human brain. It utilizes a pulsed magnetic field to induce electric pulses that act on the central nervous system, altering the membrane potential of nerve cells in the cerebral cortex to treat certain mental diseases. However, the effectiveness of TMS can be compromised by significant heat generation and the clicking noise produced by the pulse in the TMS coil.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!