Broadband CPMG sequence with short composite refocusing pulses.

J Magn Reson

School of Engineering and Applied Sciences, Harvard University, 33 Oxford Street, Cambridge, MA 02138, United States.

Published: May 2013

We demonstrate that CPMG sequences with phase-modulated refocusing pulses of the same duration as the standard 180° pulses can generate echo trains with significantly increased amplitudes compared to the standard CPMG sequence in the case when there is a large range of Larmor frequencies across the sample. The best performance is achieved with symmetric phase-alternating (SPA) composite refocusing pulses of the form α-yβ+yα-y. In comparison to standard 180° pulses, we show that with SPA refocusing pulses with α≈27° and β≈126°, it is possible to double the signal-to-noise ratio without increasing the total pulse duration or power consumption of the refocusing pulses. The increased bandwidth of these pulses more than compensates for the decrease in performance in the vicinity of resonance. To achieve the full benefit of the broadband nature of the SPA pulses in a CPMG sequence, it is necessary to combine these refocusing pulses with a broadband excitation pulse. When it is not possible to use a short, high amplitude excitation pulse, we show that phase-alternating (PA) excitation pulses are suitable for this purpose. We present a detailed analysis of the underlying spin dynamics of these new pulse sequences and confirm the simulations with experiments. We show that for samples with T1/T2>1, the new sequences in grossly inhomogeneous fields do not only generate echoes with an increased amplitude, but also with an increased decay time. Finally, we analyze the diffusion properties and show quantitatively that the broadband sequences have a substantially higher diffusion sensitivity compared with the standard CPMG sequence.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2013.01.006DOI Listing

Publication Analysis

Top Keywords

refocusing pulses
24
cpmg sequence
16
pulses
11
composite refocusing
8
standard 180°
8
180° pulses
8
compared standard
8
standard cpmg
8
excitation pulse
8
refocusing
6

Similar Publications

Fast Hadamard-Encoded 7T Spectroscopic Imaging of Human Brain.

Tomography

January 2025

NextGen Precision Health, Department of Radiology, University of Missouri Columbia, 1030 Hitt Street, Columbia, MO 65201, USA.

: The increased SNR available at 7T combined with fast readout trajectories enables accelerated spectroscopic imaging acquisitions for clinical applications. In this report, we evaluate the performance of a Hadamard slice encoding strategy with a 2D rosette trajectory for multi-slice fast spectroscopic imaging at 7T. : Moderate-TE (~40 ms) spin echo and J-refocused polarization transfer sequences were acquired with simultaneous Hadamard multi-slice excitations and rosette in-plane encoding.

View Article and Find Full Text PDF

The purpose of this study was to measure T and T relaxation times of NAD proton resonances in the downfield H MRS spectrum in human brain at 7 T in vivo and to assess the propagation of relaxation time uncertainty in NAD quantification. Downfield spectra from eight healthy volunteers were acquired at multiple echo times to measure T relaxation times, and saturation recovery data were acquired to measure T relaxation times. The downfield acquisition used a spectrally selective 90° sinc pulse for excitation centered at 9.

View Article and Find Full Text PDF

Double-quantum filtered Na NMR and MRI: Selective detection of ordered sodium in an inhomogeneous B field.

J Magn Reson

November 2024

Sir Peter Mansfield Imaging Centre, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom.

Double-quantum filtered Na NMR experiments with one or two "magic angle" (54.7°) pulses in the filter step are widely used for selective observation of sodium ions that are interacting with ordered biological structures ("ordered sodium") and hence exhibit a distribution of quadrupolar splittings in their NMR spectrum. This approach has recently been extended to Na MRI where the conventional experiment has been modified, omitting the 180° pulse to reduce the absorption of radiofrequency energy during human studies.

View Article and Find Full Text PDF

Homonuclear decoupled INADEQUATE NMR methods with improved sensitivity and resolution in solid-state NMR.

J Magn Reson

January 2025

Univ. Lille, CNRS, Centrale Lille, Univ. Artois, UMR 8181, UCCS - Unité de Catalyse et Chimie du Solide, F-59000 Lille, France. Electronic address:

The two-dimensional (2D) refocused INADEQUATE NMR experiment, which correlates double-quantum (DQ) and single-quantum (SQ) coherences, is widely used to probe the chemical connectivities in solids. Nevertheless, the multiplets along the F dimension reduce the resolution and sensitivity of this experiment. The Composite-Refocusing (CR) technique with two excitation pulses has been proposed to suppress these multiplets in 2D INADEQUATE spectra of liquids.

View Article and Find Full Text PDF

Optimizing EPR pulses for broadband excitation and refocusing.

J Magn Reson

December 2024

Department of Physics, University of Maryland Baltimore County, Baltimore, MD 21250, USA. Electronic address:

In this paper, we numerically optimize broadband pulse shapes that maximize Hahn echo amplitudes. Pulses are parameterized as neural networks (NN), nonlinear amplitude limited Fourier series (FS), and discrete time series (DT). These are compared to an optimized choice of the conventional hyperbolic secant (HS) pulse shape.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!