Plantar pressure measurement is common practice in many research and clinical protocols. While the accuracy of some plantar pressure measuring devices and methods for ensuring consistency in data collection on plantar pressure measuring devices have been reported, the reliability of different devices when testing the same individuals is not known. This study calculated intra-mat, intra-manufacturer, and inter-manufacturer reliability of plantar pressure parameters as well as the number of plantar pressure trials needed to reach a stable estimate of the mean for an individual. Twenty-two healthy adults completed ten walking trials across each of two Novel emed-x(®) and two Tekscan MatScan(®) plantar pressure measuring devices in a single visit. Intraclass correlation (ICC) was used to describe the agreement between values measured by different devices. All intra-platform reliability correlations were greater than 0.70. All inter-emed-x(®) reliability correlations were greater than 0.70. Inter-MatScan(®) reliability correlations were greater than 0.70 in 31 and 52 of 56 parameters when looking at a 10-trial average and a 5-trial average, respectively. Inter-manufacturer reliability including all four devices was greater than 0.70 for 52 and 56 of 56 parameters when looking at a 10-trial average and a 5-trial average, respectively. All parameters reached a value within 90% of an unbiased estimate of the mean within five trials. Overall, reliability results are encouraging for investigators and clinicians who may have plantar pressure data sets that include data collected on different devices.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3732469 | PMC |
http://dx.doi.org/10.1016/j.gaitpost.2013.01.028 | DOI Listing |
Med Biol Eng Comput
January 2025
Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand.
Lower limb biomechanics of chronic ankle instability (CAI) individuals has been widely investigated, but few have evaluated the internal foot mechanics in CAI. This study evaluated bone and soft tissue stress in CAI contrasted with copers and non-injured participants during a cutting task. Integrating scanned 3D foot shapes and free-form deformation, sixty-six personalized finite element foot models were developed.
View Article and Find Full Text PDFBackground: The goal of this study was to examine the effects of spinal cord stimulation (SCS) on muscle activity during walking after lower-limb amputation. Amputation results in a loss of sensory feedback and alterations in gait biomechanics, including co-contractions of antagonist muscles about the knee and ankle, and reduced pelvic obliquity range-of-motion and pelvic drop. SCS can restore sensation in the missing limb, but its effects on muscle activation and gait biomechanics have not been studied in people with lower-limb amputation.
View Article and Find Full Text PDFJ Foot Ankle Res
March 2025
The University of South Australia, Allied Health & Human Performance Unit, Adelaide, SA, Australia.
Background: This study investigated the effect of various offloading devices commonly used for the management of diabetic foot ulcerations on peak plantar pressure and pressure-time integral of the contralateral limb.
Methods: A quantitative, randomised and within-subject repeated measures study was conducted in an outpatient gait laboratory. Outpatients with unilateral diabetic foot ulcers and adequate perfusion to the lower limb without an intrinsic limb-length discrepancy who were able to walk were recruited for the study.
J Biomech
January 2025
Department of Rehabilitation Medicine, Amsterdam UMC, University of Amsterdam, Meibergdreef 9 1105 AZ, Amsterdam, the Netherlands; Amsterdam Movement Sciences, Rehabilitation & Development, Amsterdam, the Netherlands.
The offloading effectiveness of custom-made footwear for people with diabetes is assessed using plantar pressure measurements. While such pressure data is multidimensional, it is mostly analyzed using a scalar - maximum peak plantar pressure (PMax). We aimed to investigate the associations between multiple peak plantar pressure parameters for footwear assessment and determine whether this assessment depends on the chosen parameter.
View Article and Find Full Text PDFGait Posture
December 2024
Department of Medical Informatics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; Pharmaceutical Research Center, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medical Informatics, UMC-Location AMC, University of Amsterdam, Amsterdam, the Netherlands. Electronic address:
Background: Measuring plantar pressure distribution is critical for understanding foot-ground interactions, providing valuable insights for diagnosing and managing various health conditions. Since its initial studies in 1984, this field has garnered increasing attention within healthcare and medicine due to its broad applications across clinical settings.
Research Question: How does measuring plantar pressure distribution affect healthcare outcomes across different age groups and health conditions?
Methods: This review thoroughly explores the literature concerning plantar pressure distribution, focusing on studies conducted from 1984 onwards.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!