Background: New technology combining dual-energy CT with the latest gemstone detectors for spectral imaging (GSI) can be used to synthesize monochromatic images that mimic images as if different monochromatic x-ray sources were used.
Objective: The aim of the study was to evaluate the optimal combination of monochromatic image energy and adaptive statistical iterative reconstruction (ASiR) for monochromatic reconstruction of coronary CT angiography (CTA) images with the use of GSI.
Methods: Twenty consecutive patients underwent coronary CTA on a GSI capable 64-slice CT scanner (Discovery CT 750 High Definition, GE Healthcare). In 7 sets of monochromatic images (60, 65, 70, 75, 80, 90, and 110 keV; each with increasing contributions of ASiR, ie, 0%, 20%, 40%, 60%, and 80%; n = 35 reconstructions per patient), signal-to-noise (aortic root) and contrast-to-noise (left main artery) ratios were assessed. Signal-to-noise ratio, contrast-to-noise ratio, and image quality (graded on a 5-point Likert scale) were assessed in all above monochromatic reconstructions and compared with the respective standard (conventional polychromatic) image.
Results: Compared with conventional polychromatic images, reconstructions with 60 keV and 80% ASiR showed the highest improvement in contrast-to-noise (144%; P < 0.001) and signal-to-noise ratio (173%; P < 0.001). Image quality reached a plateau at 65-75 keV with 40%-60% ASiR blending, yielding a maximal image quality score improvement of 50% compared with conventional imaging (P < 0.001).
Conclusion: In coronary CTA with low radiation technique (mean radiation dose, 1.8 ± 0.7 mSv), GSI with monochromatic reconstructions (65-75 keV) and ASiR (40%-60%) offers significant noise reduction and image quality improvement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcct.2013.01.004 | DOI Listing |
Otol Neurotol
February 2025
Department of Radiology, Yale School of Medicine, New Haven, CT.
Background: Vestibular schwannoma (VS) is a common intracranial tumor that affects patients' quality of life. Reliable imaging techniques for tumor volume assessment are essential for guiding management decisions. The study aimed to compare the ABC/2 method to the gold standard planimetry method for volumetric assessment of VS.
View Article and Find Full Text PDFOptom Vis Sci
January 2025
Johnson & Johnson MedTech (Vision), Irvine, California.
Significance: Optimal meibography utilization and interpretation are hindered due to poor lid presentation, blurry images, or image artifacts and the challenges of applying clinical grading scales. These results, using the largest image dataset analyzed to date, demonstrate development of algorithms that provide standardized, real-time inference that addresses all of these limitations.
Purpose: This study aimed to develop and validate an algorithmic pipeline to automate and standardize meibomian gland absence assessment and interpretation.
PLoS One
January 2025
Medical Image Processing Research Group (MIPRG), Dept. of Elect. & Comp. Engineering, COMSATS University Islamabad, Islamabad, Pakistan.
Recovering diagnostic-quality cardiac MR images from highly under-sampled data is a current research focus, particularly in addressing cardiac and respiratory motion. Techniques such as Compressed Sensing (CS) and Parallel Imaging (pMRI) have been proposed to accelerate MRI data acquisition and improve image quality. However, these methods have limitations in high spatial-resolution applications, often resulting in blurring or residual artifacts.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Neurology, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
Purpose: A relative afferent pupillary defect (RAPD) is a characteristic clinical sign of optic neuritis (ON). Here, we systematically evaluated ultrasound pupillometry (UP) for the detection of an RAPD in patients with ON, including a comparison with infrared video pupillometry (IVP), the gold standard for objective pupillometry.
Materials And Methods: We enrolled 40 patients with acute (n = 9) or past (n = 31) ON (ON+), 31 patients with multiple sclerosis (MS) without prior ON, and 50 healthy controls (HC) in a cross-sectional observational study.
Medicine (Baltimore)
January 2025
Department of Pathology, Keck School of Medicine, University of Southern California, Los Angeles, CA.
Rationale: Solitary fibrous tumors (SFTs) are spindle cell tumors that typically occur in the pleura and peritoneum, but very rarely in the stomach. To our best knowledge, there are only 10 cases reported in English literature. We reported a case of primary stomach SFT and summarized the characteristics of all previous cases, suggesting that pathologists and surgeons should include this disease in the differential diagnosis list of primary mesenchymal tumor of the stomach.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!