Methods of NO detection in exhaled breath.

J Breath Res

Life Science Trace Gas Facility, Molecular and Laser Physics, Institute for Molecules and Materials, Radboud University, Nijmegen, The Netherlands.

Published: March 2013

There is still an unexplored potential for exhaled nitric oxide (NO) in many clinical applications. This study presents an overview of the currently available methods for monitoring NO in exhaled breath and the use of the modelling of NO production and transport in the lung in clinical practice. Three technologies are described, namely chemiluminescence, electrochemical sensing and laser-based detection with their advantages and limitations. Comparisons are made in terms of sensitivity, time response, size, costs and suitability for clinical purposes. The importance of the flow rate for NO sampling is discussed from the perspective of the recent recommendations for standardized procedures for online and offline NO measurement. The measurement of NO at one flow rate, such as 50 ml s(-1), can neither determine the alveolar site/peripheral contribution nor quantify the difference in NO diffusion from the airways walls. The use of NO modelling (linear or non-linear approach) can solve this problem and provide useful information about the source of NO. This is of great value in diagnostic procedures of respiratory diseases and in treatment with anti-inflammatory drugs.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1752-7155/7/1/017104DOI Listing

Publication Analysis

Top Keywords

exhaled breath
8
flow rate
8
methods detection
4
detection exhaled
4
breath unexplored
4
unexplored potential
4
potential exhaled
4
exhaled nitric
4
nitric oxide
4
oxide clinical
4

Similar Publications

Background: Impaired oxidation of branched chain amino acids may give rise to volatile organic compounds (VOCs). We hypothesized that VOCs will be present in exhaled breath of participants with propionic acidemia (PA), and their relative abundance would correlate with clinical and biochemical characteristics of the disease.

Methods: We enrolled 5 affected participants from a natural history study of PA (ClinicalTrials.

View Article and Find Full Text PDF

Cement dust is a primary contributor to air pollution and is responsible for causing numerous respiratory diseases. The impact of cement dust exposure on the respiratory health of residents is increasing owing to the demand for construction associated with urbanization. Long-term inhalation of cement dust leads to a reduction in lung function, alterations in airway structure, increased inhalation and exhalation resistance, and heightened work of breath.

View Article and Find Full Text PDF

Biomarkers.

Alzheimers Dement

December 2024

Xiangya Hospital, Central South University, Changsha, Hunan, China.

Background: Existing biomarkers including cerebrospinal fluid and positron emission tomography for Alzheimer's disease (AD) diagnosis are relatively invasive and expensive. Application of exhaled breath collection and volatile organic compound (VOC) detection for AD diagnosis remains unclear.

Method: In this cross-sectional study, high-pressure photon ionization time-of-flight mass spectrometry (HPPI-ToF-MS) was used to detect VOCs from breath in three datasets and patients diagnosed as Parkinson's disease (PD).

View Article and Find Full Text PDF

Background: Advances in imaging technology have enhanced the detection of pulmonary nodules. However, determining malignancy often requires invasive procedures or repeated radiation exposure, underscoring the need for safer, noninvasive diagnostic alternatives. Analyzing exhaled volatile organic compounds (VOCs) shows promise, yet its effectiveness in assessing the malignancy of pulmonary nodules remains underexplored.

View Article and Find Full Text PDF

Background: Mixed exhaled air has been widely used to determine exhaled propofol concentrations with online analyzers, but changes in dead space proportions may lead to inaccurate assessments of critical drug concentration data. This study proposes a method to correct propofol concentration in mixed air by estimating pulmonary dead space through reconstructing volumetric capnography (Vcap) from time-CO and time-volume curves, validated with vacuum ultraviolet time-of-flight mass spectrometry (VUV-TOF MS).

Methods: Existing monitoring parameters, including time-volume and time-CO curves, were used to determine Vcap.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!