There is still an unexplored potential for exhaled nitric oxide (NO) in many clinical applications. This study presents an overview of the currently available methods for monitoring NO in exhaled breath and the use of the modelling of NO production and transport in the lung in clinical practice. Three technologies are described, namely chemiluminescence, electrochemical sensing and laser-based detection with their advantages and limitations. Comparisons are made in terms of sensitivity, time response, size, costs and suitability for clinical purposes. The importance of the flow rate for NO sampling is discussed from the perspective of the recent recommendations for standardized procedures for online and offline NO measurement. The measurement of NO at one flow rate, such as 50 ml s(-1), can neither determine the alveolar site/peripheral contribution nor quantify the difference in NO diffusion from the airways walls. The use of NO modelling (linear or non-linear approach) can solve this problem and provide useful information about the source of NO. This is of great value in diagnostic procedures of respiratory diseases and in treatment with anti-inflammatory drugs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1752-7155/7/1/017104 | DOI Listing |
Mol Genet Metab
December 2024
National Human Genome Research Institute, Bethesda, MD, USA. Electronic address:
Background: Impaired oxidation of branched chain amino acids may give rise to volatile organic compounds (VOCs). We hypothesized that VOCs will be present in exhaled breath of participants with propionic acidemia (PA), and their relative abundance would correlate with clinical and biochemical characteristics of the disease.
Methods: We enrolled 5 affected participants from a natural history study of PA (ClinicalTrials.
J Biomech
January 2025
School of Mechanical Engineering, Kyungpook National University & IEDT, Daegu, South Korea. Electronic address:
Cement dust is a primary contributor to air pollution and is responsible for causing numerous respiratory diseases. The impact of cement dust exposure on the respiratory health of residents is increasing owing to the demand for construction associated with urbanization. Long-term inhalation of cement dust leads to a reduction in lung function, alterations in airway structure, increased inhalation and exhalation resistance, and heightened work of breath.
View Article and Find Full Text PDFAlzheimers Dement
December 2024
Xiangya Hospital, Central South University, Changsha, Hunan, China.
Background: Existing biomarkers including cerebrospinal fluid and positron emission tomography for Alzheimer's disease (AD) diagnosis are relatively invasive and expensive. Application of exhaled breath collection and volatile organic compound (VOC) detection for AD diagnosis remains unclear.
Method: In this cross-sectional study, high-pressure photon ionization time-of-flight mass spectrometry (HPPI-ToF-MS) was used to detect VOCs from breath in three datasets and patients diagnosed as Parkinson's disease (PD).
Cancer Med
January 2025
Department of Health Management Center, Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, Jiangsu, China.
Background: Advances in imaging technology have enhanced the detection of pulmonary nodules. However, determining malignancy often requires invasive procedures or repeated radiation exposure, underscoring the need for safer, noninvasive diagnostic alternatives. Analyzing exhaled volatile organic compounds (VOCs) shows promise, yet its effectiveness in assessing the malignancy of pulmonary nodules remains underexplored.
View Article and Find Full Text PDFBMC Vet Res
January 2025
Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu, China.
Background: Mixed exhaled air has been widely used to determine exhaled propofol concentrations with online analyzers, but changes in dead space proportions may lead to inaccurate assessments of critical drug concentration data. This study proposes a method to correct propofol concentration in mixed air by estimating pulmonary dead space through reconstructing volumetric capnography (Vcap) from time-CO and time-volume curves, validated with vacuum ultraviolet time-of-flight mass spectrometry (VUV-TOF MS).
Methods: Existing monitoring parameters, including time-volume and time-CO curves, were used to determine Vcap.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!