In this paper, a laboratory goniometer system for performing multi-angular measurements under controlled illumination conditions is described. A commercially available robotic arm enables the acquisition of a large number of measurements over the full hemisphere within a short time span making it much faster than other goniometers. In addition, the presented set-up enables assessment of anisotropic reflectance and emittance behaviour of soils, leaves and small canopies. Mounting a spectrometer enables acquisition of either hemispherical measurements or measurements in the horizontal plane. Mounting a thermal camera allows directional observations of the thermal emittance. This paper also presents three showcases of these different measurement set-ups in order to illustrate its possibilities. Finally, suggestions for applying this instrument and for future research directions are given, including linking the measured reflectance anisotropy with physically-based anisotropy models on the one hand and combining them with field goniometry measurements for joint analysis with remote sensing data on the other hand. The speed and flexibility of the system offer a large added value to the existing pool of laboratory goniometers.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3571842 | PMC |
http://dx.doi.org/10.3390/s121217358 | DOI Listing |
Life (Basel)
November 2024
Department of Electronic Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
After a fracture, patients have reduced willingness to bend and extend their elbow joint due to pain, resulting in muscle atrophy, contracture, and stiffness around the elbow. Moreover, this may lead to progressive atrophy of the muscles around the elbow, resulting in permanent functional loss. Currently, a goniometer is used to measure the range of motion, ROM, to evaluate the recovery of the affected limb.
View Article and Find Full Text PDFObjective: Recent advances in smartphone applications for measuring range of motion have led to the development of the physio master application by Trinus Laboratory, Navi Mumbai. This app, equipped with a magnetometer and accelerometer, accurately measures the angle between starting and ending device positions. This study aimed to assess the inter-rater and intra-rater reliability, as well as the criterion validity, of the physio master application in measuring cervical range of motion in healthy individuals.
View Article and Find Full Text PDFJ Vet Med Educ
August 2024
Department of Small Animal Clinical Sciences, Michigan State University College of Veterinary Medicine 736 Wilson Rd. East Lansing, MI 48824.
Goniometry is an essential skill used in veterinary rehabilitation settings to monitor orthopedic conditions. Our objectives were to create a normal canine stifle goniometry model and to compare students' confidence and accuracy in performing goniometry with exposure to either the model or traditional teaching methods. We hypothesized that students would demonstrate goniometry skills more confidently and accurately after using a simulation model than those given traditional materials.
View Article and Find Full Text PDFJ Biomech
November 2024
Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh PA, USA. Electronic address:
Cadaveric and computer simulations suggest lateral humeral offset (LHO) and humeral retroversion (HR) are associated with strength and range of motion (ROM) after reverse total shoulder arthroplasty (rTSA), butin vivodata is lacking. This study aimed to evaluate the effects of implant parameters (i.e.
View Article and Find Full Text PDFArch Phys Med Rehabil
September 2024
School of Sports Medicine and Rehabilitation, Beijing Sport University, Beijing, China; Key Laboratory for Performance Training & Recovery of General Administration of Sport, Beijing Sport University, Beijing, China. Electronic address:
Objective: To observe the effect of uphill running and the combined effect of uphill running plus joint mobilizations on dynamic stability and ankle dorsiflexion in young adults with chronic ankle instability (CAI).
Design: Four-arm randomized controlled trial.
Setting: A college rehabilitation center.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!