Loading and distribution of a model small molecule drug in poly(N-isopropylacrylamide) brushes: a neutron reflectometry and AFM study.

Langmuir

Department of Chemistry and Biochemistry, Notre Dame Center for Nano Science and Technology, University of Notre Dame, Notre Dame, Indiana 46556, United States.

Published: March 2013

The structure of a hydrated poly(N-isopropylacrylamide) brush loaded with 5 vol % Isoniazid is studied as a function of temperature using neutron reflectometry (NR) and atomic force microscopy (AFM). NR measurements show that Isoniazid increases the thickness of the brush before, during and after the polymer collapse, and it is retained inside the brush at all measured temperatures. The Isoniazid concentration in the expanded brush is ~14% higher than in the bulk solution, and the concentration nearly doubles in the collapsed polymer, suggesting stronger binding between Isoniazid and the polymer compared to water, even at temperatures below the lower critical solution temperature (LCST) where the polymer is hydrophilic. Typically, additives that bind strongly to the polymer backbone and increase the hydrophilicity of the polymer will delay the onset of the LCST, which is suggested by AFM and NR measurements. The extent of small-molecule loading and distribution throughout a thermo-responsive polymer brush, such as pNIPAAm, will have important consequences for applications such as drug delivery and gating.

Download full-text PDF

Source
http://dx.doi.org/10.1021/la305088kDOI Listing

Publication Analysis

Top Keywords

loading distribution
8
neutron reflectometry
8
afm measurements
8
polymer
7
brush
5
distribution model
4
model small
4
small molecule
4
molecule drug
4
drug polyn-isopropylacrylamide
4

Similar Publications

Opportunistic screening is essential to improve the identification of individuals with osteoporosis. Our group has utilized image texture features to assess bone quality using clinical MRIs. We have previously demonstrated that greater heterogeneity of MRI texture related to history of fragility fractures, lower bone density, and worse microarchitecture.

View Article and Find Full Text PDF

Optimal power scheduling in real-time distribution systems using crow search algorithm for enhanced microgrid performance.

Sci Rep

December 2024

Department of Theoretical Electrical Engineering and Diagnostics of Electrical Equipment, Institute of Electrodynamics, National Academy of Sciences of Ukraine, Beresteyskiy, 56, Kyiv-57, 03680, Ukraine.

Microgrids (MGs) have gained significant attention over the past two decades due to their advantages in service reliability, easy integration of renewable energy sources, high efficiency, and enhanced power quality. In India, low-voltage side customers face significant challenges in terms of power supply continuity and voltage regulation. This paper presents a novel approach for optimal power scheduling in a microgrid, aiming to provide uninterrupted power supply with improved voltage regulation (VR).

View Article and Find Full Text PDF

The design of drill pipe joint thread with unequal taper is proposed to investigate the fracture failure of the API NC38 used in the drill pipe joint of the SU36-8-4H2 well. The effect of changes in thread taper on the stress distribution and mechanical properties of drill pipe joints is analyzed and compared with the API standard thread to determine the optimal thread structure with unequal taper. The results reveal highly concentrated stress at the last engaged thread root of API NC38 single-shoulder thread (SUT) may cause early yield failure of the joint threads.

View Article and Find Full Text PDF

This study presents a novel framework for advancing sustainable urban logistics and distribution systems, with a pivotal focus on fast charging and power exchange modalities as the cornerstone of our research endeavors. Our central contribution encompasses the formulation of an innovative electric vehicle path optimization model, whose paramount objective is to minimize overall operational costs. Integrating V2G technology, we facilitate sophisticated slow charging and discharging management of EVs upon their return to distribution centers, enhancing resource utilization.

View Article and Find Full Text PDF

Residual dentin thickness and biomechanical performance of post-and-core-restored mandibular premolars: A finite element analysis study.

J Prosthet Dent

December 2024

Associate Chief Physician, Department of Prosthodontic, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China. Electronic address:

Statement Of Problem: Endodontically treated teeth often require post-and-core restorations for structural support because of extensive hard tissue loss. Assessment of the effect of the residual dentin thickness on the biomechanical performance of these restorations is lacking.

Purpose: The purpose of this study was to evaluate the residual dentin thickness in mandibular premolars after post-and-core restorations using cone beam computed tomography (CBCT) and to analyze the stress distribution with finite element analysis (FEA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!