Purpose: Despite numerous publications describing the ability of prospective motion correction to improve image quality in magnetic resonance imaging of the brain, a reliable approach to assess this improvement is still missing. A method that accurately reproduces motion artifacts correctable with prospective motion correction is developed, and enables the quantification of the improvements achieved.

Methods: A software interface was developed to simulate rigid body motion by changing the scanning coordinate system relative to the object. Thus, tracking data recorded during a patient scan can be used to reproduce the prevented motion artifacts on a volunteer or a phantom. The influence of physiological motion on image quality was investigated by filtering these data. Finally, the method was used to reproduce and quantify the motion artifacts prevented in a patient scan.

Results: The accuracy of the method was tested in phantom experiments and in vivo. The calculated quality factor, as well as a visual inspection of the reproduced artifacts shows a good correspondence to the original.

Conclusion: Precise reproduction of motion artifacts assists qualification of prospective motion correction strategies. The presented method provides an important tool to investigate the effects of rigid body motion on a wide range of sequences, and to quantify the improvement in image quality through prospective motion correction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3674114PMC
http://dx.doi.org/10.1002/mrm.24645DOI Listing

Publication Analysis

Top Keywords

motion artifacts
20
prospective motion
20
motion correction
20
motion
12
image quality
12
reproduction motion
8
rigid body
8
body motion
8
artifacts
6
prospective
5

Similar Publications

In image-guided radiotherapy (IGRT), four-dimensional cone-beam computed tomography (4D-CBCT) is critical for assessing tumor motion during a patients breathing cycle prior to beam delivery. However, generating 4D-CBCT images with sufficient quality requires significantly more projection images than a standard 3D-CBCT scan, leading to extended scanning times and increased imaging dose to the patient. To address these limitations, there is a strong demand for methods capable of reconstructing high-quality 4D-CBCT images from a 1-minute 3D-CBCT acquisition.

View Article and Find Full Text PDF

Purpose: We investigated the feasibility and advantages of using non-contrast CT calcium score (CTCS) images to assess pericoronary adipose tissue (PCAT) and its association with major adverse cardiovascular events (MACE). PCAT features from coronary computed tomography angiography (CCTA) have been shown to be associated with cardiovascular risk but are potentially confounded by iodine. If PCAT in CTCS images can be similarly analyzed, it would avoid this issue and enable its inclusion in formal risk assessment from readily available, low-cost CTCS images.

View Article and Find Full Text PDF

Magnetic Resonance Imaging is a cornerstone of medical diagnostics, providing high-quality soft tissue contrast through non-invasive methods. However, MRI technology faces critical limitations in imaging speed and resolution. Prolonged scan times not only increase patient discomfort but also contribute to motion artifacts, further compromising image quality.

View Article and Find Full Text PDF

Generally, the electrocardiography (ECG) system plays an important role in preventing and diagnosing heart diseases. To further improve the amenity and convenience of using an ECG system, we built a customized capacitive electrocardiography (cECG) system with one wet electrode, sixteen non-contact electrodes, two ADS1299 chips, and one STM32F303-based microcontroller unit (MCU). This new cECG system could acquire, save, and display the ECG data in real time.

View Article and Find Full Text PDF

Breath-hold T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) magnetic resonance imaging (MRI) of the upper abdomen with a slice thickness below 5 mm suffers from high image noise and blurring. The purpose of this prospective study was to improve image quality and accelerate imaging acquisition by using single-breath-hold T2-weighted HASTE with deep learning (DL) reconstruction (DL-HASTE) with a 3 mm slice thickness. MRI of the upper abdomen with DL-HASTE was performed in 35 participants (5 healthy volunteers and 30 patients) at 3 Tesla.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!