Tumor angiogenesis is important in the growth and metastasis of malignant tumors. In our previous study, we demonstrated that an arginine-arginine-leucine (RRL) peptide is a tumor endothelial cell-specific binding sequence that may be used as a molecular probe for the imaging of malignant tumors in vivo. The aim of the present study was to further explore the characteristics of 131I‑RRL by biodistribution tests, and to estimate the radiation dosimetry of 131I‑RRL for humans using mice data. The RRL peptide was radiolabeled with 131I by a chloramine-T (CH-T) method. The radiolabeling efficiency and radiochemical purity were then characterized in vitro. 131I‑RRL was injected intravenously into B16 xenograft-bearing Kunming mice. Biodistribution analysis and in vivo imaging were performed periodically. The radiation dosimetry in humans was calculated according to the organ distribution and the standard medical internal radiation dose (MIRD) method in mice. All data were analyzed by statistical and MIRDOSE 3.1 software. The labeling efficiency of 131I‑RRL reached 70.0±2.91% (n=5), and the radiochemical purity exceeded 95% following purification. In mice bearing B16 xenografts, 131I‑RRL rapidly cleared from the blood and predominantly accumulated in the kidneys, the stomach and the tumor tissue. The specific uptake of 131I‑RRL in the tumor increased over time and was significantly higher than that of the other organs, 24-72 h following injection (P<0.05). The ratio of tumor-to-skeletal muscle (T/SM) tissue exceeded 4.75, and the ratio of the tumor-to-blood (T/B) tissue peaked at 3.36. In the single-photon emission computed tomography (SPECT) imaging of Kunming mice bearing B16 xenografts, the tumors were clearly identifiable at 6 h, and significant uptake was evident 24-72 h following administration of 131I‑RRL. The effective dose for the adult male dosimetric model was estimated to be 0.0293 mSv/MBq. Higher absorbed doses were estimated for the stomach (0.102 mGy/MBq), the small intestines (0.0699 mGy/MBq), the kidneys (0.0611 mGy/MBq) and the liver (0.055 mGy/MBq). These results highlight the potential of 131I‑RRL as a ligand for the SPECT imaging of tumors. Administration of 131I‑RRL led to a reasonable radiation dose burden and was safe for human use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3892/mmr.2013.1338 | DOI Listing |
Technol Cancer Res Treat
January 2025
Department of Radiation Oncology, Cancer Hospital of Shantou University Medical College, Shantou, Guangdong, PR China.
Purpose: To evaluate the impact of patient setup errors on the dosimetry and radiobiological models of intensity-modulated radiotherapy (IMRT) for esophageal cancer.
Methods And Materials: This retrospective study with 56 patients in thermoplastic mask (TM) and vacuum bag (VB) groups utilized real setup-error (RSE) data from cone-beam CT scans to generate simulated setup-error (SSE) data following a normal distribution. The SSE data were applied to simulate all treatment fractions per patient by shifting the plan isocenter and recalculating the dose.
Front Oncol
January 2025
Department of Clinical Development, POINT Biopharma, a wholly owned subsidiary of Eli Lilly and Company, Indianapolis, IN, United States.
Introduction: SPLASH (NCT04647526) is a multicenter phase III trial evaluating the efficacy and safety of [Lu]Lu-PNT2002 radioligand therapy in metastatic castration-resistant prostate cancer (mCRPC). This study leveraged a lead-in phase to assess tissue dosimetry and evaluate preliminary safety and efficacy, prior to expansion into a randomized phase. Here we report those results.
View Article and Find Full Text PDFCurr Radiopharm
January 2025
Department of Nuclear Medicine, Istanbul University-Cerrahpaşa, Cerrahpaşa Faculty of Medicine, Istanbul, Turkey.
Aim: This study intended to compare the radiation dose estimates to target and nontarget liver compartments from 99mTc-MAA SPECT/CT and 90Y-PET/MR scans in liver tumors treated by 90Y-glass microspheres.
Material And Methods: Dose estimation was performed for twenty-three eligible patients (13M, 10F) after 99mTc-MAA simulation using SPECT/CT imaging, and over 90Y-PET/MR images after 90Y-microsphere therapy. Simplicit90Y™ software was used for voxel-based dosimetry over the liver parenchyma.
Photochem Photobiol
January 2025
Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Photodynamic therapy (PDT) has shown promise as an adjuvant treatment for malignant pleural mesothelioma when combined with surgical resection. Accurate light dosimetry is critical for treatment efficacy. This study presents an improved method for analyzing light fluence distribution in pleural PDT using a standardized anatomical coordinate system and advanced computational modeling.
View Article and Find Full Text PDFRadiology
January 2025
From the Department of Diagnostic, Molecular, and Interventional Radiology, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029 (Y.Z., D.F.Y., C.I.H.); and Department of Radiology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China (Y.Z.).
Lung cancer is the leading cause of cancer deaths globally. In various trials, the ability of low-dose CT screening to diagnose early lung cancers leads to high cure rates. It is widely accepted that the potential benefits of low-dose CT screening for lung cancer outweigh the harms.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!