AI Article Synopsis

  • - The study compares two techniques for implanting left ventricular (LV) leads during cardiac resynchronization therapy (CRT): telescoping-support catheters (group TS) and standard over-the-wire methods (group OTW).
  • - Results showed that group TS had a significantly lower failure rate for lead placements (1.9% vs 8.1%) and achieved optimal lead positioning more often (87% vs 75%).
  • - Additionally, the telescoping-support method reduced fluoroscopy procedure time, averaging 29.6 minutes compared to 41.9 minutes for the standard method.

Article Abstract

Background: Proper positioning of the left ventricular (LV) lead improves clinical outcomes and survival in patients receiving cardiac resynchronization therapy (CRT). Techniques of LV lead insertion using contrast injection and a telescoping system of delivery catheters to support advancement of the lead into the target branch may allow more efficient, targeted lead placement. We sought to evaluate the impact of an LV lead implant approach using telescoping-support catheters (group TS) on success rate, lead location, and procedural time compared to standard over-the-wire implant techniques (group OTW).

Methods: Four hundred thirty-seven consecutive patients undergoing CRT implantation were divided into group TS (n = 105) or group OTW (n = 332) based upon a review of the operative technique used for LV lead implantation. The primary outcome was success of LV lead implantation at the index procedure. Secondary endpoints included optimal positioning of the LV lead and reduction in procedural fluoroscopy time.

Results: Failed LV lead placement was lower (1.9% vs 8.1%, P = 0.02) and optimal lead positioning was achieved more often for group TS than group OTW (87% vs 75%, P = 0.01). In addition, there were significantly shorter fluoroscopy times for group TS versus group OTW (29.6 minutes vs 41.9 minutes, P < 0.01).

Conclusion: A CRT-implant approach using contrast injection and a telescoping-support catheter system results in fewer failed LV lead implants, improved LV lead location, and shorter procedure times.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.12103DOI Listing

Publication Analysis

Top Keywords

lead
14
lead placement
12
group otw
12
telescoping-support catheter
8
catheter system
8
left ventricular
8
ventricular lead
8
cardiac resynchronization
8
resynchronization therapy
8
contrast injection
8

Similar Publications

Fluid administration is widely used to treat hypotension in patients undergoing veno-venous extracorporeal membrane oxygenation (VV-ECMO). However, excessive fluid administration may lead to fluid overload can aggravate acute respiratory distress syndrome (ARDS) and increase patient mortality, predicting fluid responsiveness is of great significance for VV-ECMO patients. This prospective single-center study was conducted in a medical intensive care unit (ICU) and finally included 51 VV-ECMO patients with ARDS in the prone position (PP).

View Article and Find Full Text PDF

Desert locusts, notorious for their ruinous impact on agriculture, threaten over 20% of Earth's landmass, prompting billions in losses and global food scarcity concerns. With billions of these locusts invading agrarian lands, this is no longer a thing of the past. Recent invasions, such as those in India, where losses reached US$ 3 billion in 2019-20 alone, underscore the urgency of action.

View Article and Find Full Text PDF

A nationwide cross-sectional study in Saudi Arabia for the assessment of understanding and practices of clinicians towards personalized genetic testing.

Sci Rep

December 2024

Medical Genomics Research Department, King Abdullah International Medical Research Center, King Saud bin Abdulaziz University for Health Sciences, Ministry of National Guard Health Affairs, Riyadh, Saudi Arabia.

In order to plan and facilitate the culture of personalized / precision medicine in medical practices within any healthcare institution, it is requisite for healthcare professionals like clinicians to have a clear understanding and approach towards the practices of personalized genetic testing. This nationwide cross-sectional study aimed to measure the perceptions and knowledge of clinicians towards personalized genetic testing and assess their current practices of personalized genetic testing in clinical settings through an online self-administered questionnaire in Saudi Arabia. The results of the study revealed that almost two-fifths of participants were responsible for ordering genetic tests directly (39.

View Article and Find Full Text PDF

Currently, the barrier to successful lung transplantation is ischemia and reperfusion injury, which can lead to the development of bronchiolitis obliterans. Paclitaxel and methotrexate are drugs known to inhibit cell proliferation and have anti-inflammatory effects, and the association of these drugs with cholesterol-rich nanoparticles has been shown to be beneficial in the treatment of other transplanted organs. Thirty-three male Sprague Dawley rats were divided into 3 groups: Basal group, no intervention; Control group, received only nanoparticles; Drug group, paclitaxel and methotrexate treatment.

View Article and Find Full Text PDF

The unintended consequences of polypharmacy pose significant risks to older adults. The complexities of managing numerous medications from multiple prescribers demand a comprehensive approach to mitigate harms. Pharmacist-led clinics have been shown to improve outcomes in patients with diabetes and hypertension.