AI Article Synopsis

  • Hot water recirculation systems (HWRS) in hotels and nursing homes are linked to legionellosis outbreaks, particularly in Spain.
  • 231 water samples were analyzed, revealing that Legionella pneumophila was the most common species, with factors like protozoa and temperatures influencing its presence.
  • Findings indicated that higher heterotrophic plate counts (HPC) and lower temperatures correlated with increased Legionella risk, while higher copper levels and temperatures above 55 °C reduced the risk, emphasizing the importance of monitoring these parameters.

Article Abstract

Hot water recirculation systems (HWRS) in hotels and nursing homes, which are common in countries such as Spain, have been related to outbreaks of legionellosis. To establish the relationships of microbial and physicochemical parameters, especially protozoa, with the occurrence of Legionella in HWRS, 231 samples from hotels and nursing homes were analysed for Legionella, protozoa, heterotrophic plate counts (HPC) at 22 and 37 °C, Pseudomonas, metals, temperature and others. Legionella pneumophila was the dominant species isolated, and 22 % were sg. 1. The sampling method became particularly important in order to define which factors were involved on the occurrence of Legionella. Results showed that the bacteria and the accompanying microbiota were more abundant in the first flush water whose temperature was lower. The bacteria occurred in those samples with high HPC and were inversely correlated with high temperatures. Multivariate regression showed that a concentration above 1 × 10(5) CFU/100 mL of HPC at 37 °C, Fe above 0.095 ppm and the presence of protozoa increased significantly the risk of Legionella colonization, while univariant regression showed that the presence of Cu above 0.76 ppm and temperature above 55 °C diminished it. Therefore, to reduce the risk associated with Legionella occurrence in HWRS these parameters should be taken into consideration.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-013-1557-5DOI Listing

Publication Analysis

Top Keywords

microbial physicochemical
8
physicochemical parameters
8
associated legionella
8
hot water
8
water recirculation
8
recirculation systems
8
hotels nursing
8
nursing homes
8
occurrence legionella
8
hpc °c
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!