A pilot trial of the iPad tablet computer as a portable device for visual acuity testing.

J Telemed Telecare

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Centre, Sun Yat-sen University, 54S Xianlie Road, Guangzhou 510060, China.

Published: January 2013

We evaluated the accuracy of an app for the iPad tablet computer (Eye Chart Pro) as a portable method of visual acuity (VA) testing. A total of 120 consecutive patients (240 eyes) underwent visual acuity test with an iPad 2 and a conventional light-box chart. The logMAR VA results from the iPad were significantly higher than those from the light-box (P < 0.001). Bland-Altman analysis revealed a mean difference (bias) of 0.02 logMAR units between the VA results from the iPad chart and the light-box chart, with 95% limits of agreement of -0.14 to 0.19. Two groups of patients were defined: in Group 1 there were 182 eyes with VA better than 0.1 according to the light-box VA test. The median logMAR VA by the iPad was 0.54 and by the light-box chart it was 0.52; there was no significant difference between them (P = 0.69). In Group 2 there were 58 eyes with VA equal to or worse than 0.1 according to the light-box VA test. The median logMAR VA by the iPad was 1.26 and was 1.10 by the light box; the result from the iPad was significantly lower (P < 0.001). The Eye Chart Pro app installed on the iPad is reliable for VA testing only when the Snellen VA is better than 0.1 (20/200).

Download full-text PDF

Source
http://dx.doi.org/10.1177/1357633X12474964DOI Listing

Publication Analysis

Top Keywords

visual acuity
12
light-box chart
12
logmar ipad
12
ipad
9
ipad tablet
8
tablet computer
8
acuity testing
8
eye chart
8
chart pro
8
light-box test
8

Similar Publications

Purpose: We describe an atypical presentation of an 11-year-old female with enhanced S-cone syndrome (ESCS).

Methods: Case report. The patient underwent a thorough ophthalmic examination and investigations such as colour fundus photography, optical coherence tomography, fundus autofluorescence, fluorescein and indocyanine angiography, an electroretinogram and genetic testing.

View Article and Find Full Text PDF

Purpose: We investigated changes in macular topography and their association with visual acuity and metamorphopsia in the idiopathic epiretinal membrane (iERM).

Methods: Twenty-four eyes that underwent vitrectomy and ERM removal with internal limiting membrane peeling were included in this study. Best-corrected visual acuity (BCVA) and horizontal/vertical metamorphopsia scores (h and vM-scores in the M-chart) were assessed.

View Article and Find Full Text PDF

Purpose: To evaluate prevalence and incidence rates of pigmentary maculopathy and retinopathy (PM/PR), and visual acuity (VA) changes in patients exposed to pentosan polysulfate sodium (PPS) and in patients with interstitial cystitis (IC) not exposed to PPS.

Methods: This is a retrospective cohort study (January 2015-March 2021) which included adult de-identified patients from the American Academy of Ophthalmology IRIS® Registry (Intelligent Research in Sight) and Komodo Health database. Three patient cohorts were identified: two PPS-exposed patient cohorts, and Non-PPS-exposed IC patient cohort.

View Article and Find Full Text PDF

Importance: Bietti crystalline dystrophy (BCD) is a severe genetic retinopathy caused by variants in the CYP4V2 gene. Currently, there is no approved treatment for BCD.

Objective: To evaluate safety and vision outcomes following gene therapy with adeno-associated virus (AAV) encoding CYP4V2 (rAAV-hCYP4V2, NGGT001 [Next Generation Gene Therapeutics]).

View Article and Find Full Text PDF

Attractive and repulsive visual aftereffects depend on stimulus contrast.

J Vis

January 2025

Laboratoire des Systèmes Perceptifs, Département d'études cognitives, École normale supérieure, PSL University, France.

Visual perception has been described as a dynamic process where incoming visual information is combined with what has been seen before to form the current percept. Such a process can result in multiple visual aftereffects that can be attractive toward or repulsive away from past visual stimulation. A lot of research has been conducted on what functional role the mechanisms that produce these aftereffects may play.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!