Hip resurfacing arthroplasty (HRA) is a viable alternative to total hip arthroplasty (THA) in the younger, active adult with degenerative hip disease. However, hip resurfacing has proven to be technically demanding, as accurate component positioning is crucial for success, yet difficult to obtain. Risks of malpositioning of the femoral head include femoral neck notching, varus/valgus malalignment, and femoral neck fracture, while malpositioning of either component may lead to increased edge loading and metal ion levels. A thorough preoperative plan, including a review of clinical findings, radiographic studies, and surgical templating for component size and positioning improves intraoperative accuracy and precision. Key aspects of formulating a methodical preoperative plan for HRA are reviewed. Pertinent aspects of the clinical and radiographic examinations, the technique of preoperative templating, its intraoperative application, clinical outcomes of various preoperative templating systems and intraoperative alignment guides, and the senior author's (EPS) preferred technique are presented.
Download full-text PDF |
Source |
---|
Sensors (Basel)
January 2025
School of Biomedical Engineering, Tsinghua University, Shuang Qing Road, Beijing 100084, China.
Mastoidectomy is critical in acoustic neuroma surgery, where precise planning of the bone milling area is essential for surgical navigation. The complexity of representing the irregular volumetric area and the presence of high-risk structures (e.g.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Plastic, Aesthetic and Reconstructive Surgery, Kepler University Hospital Linz, Krankenhausstrasse 9, 4020 Linz, Austria.
Vascularized bone grafts have been successfully established for complex bone defects. The integration of three-dimensional (3D) simulation and printing technology may aid in more precise surgical planning and intraoperative bone shaping. The purpose of the present study was to describe the implementation and surgical application of this innovative technology for bone reconstruction.
View Article and Find Full Text PDFJ Neurol Surg Rep
January 2025
Department of Neurosurgery, Hospital of the German Armed Forces, Westerstede, Germany.
Although osteosarcomas are the most frequent primary malignant bone tumors, the primary cranial manifestation of this condition is very rare with only a limited number of cases presented in the literature. We present the case of a 20-year-old male patient who underwent single-session surgical intervention for resection of right frontal osteosarcoma with a tailor-made craniotomy and cranioplasty using virtually designed 3D-printed templates and molds. Subsequently, the patient was treated according to the EURAMOS protocol and received adjuvant systemic chemotherapy.
View Article and Find Full Text PDFHead Neck
January 2025
Division of Otolaryngology, Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada.
Background: Virtual surgical planning (VSP) with simple cutting templates could help surgeons preoperatively plan scapula reconstructions in the vertical and horizontal orientations.
Methods: Virtually, eight defects were created in ten healthy mandibles and reconstructed with the subject-specific scapula vertically and horizontally. In the clinical series, 15 single-piece scapula mandible reconstructions planned with in-house VSP and guided with simple templates were compared with 15 freehand reconstructions.
Sci Rep
January 2025
Robotics Institute, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA.
Patient-specific templating (PST), which is a sister procedure to patient-specific instrumentation (PSI) but hospital-based, is relatively less complex and less expensive than robotics and navigation. However, there are some concerns about the PST including the process of preoperative planning, 3D printing and material, positioning of PST intraoperatively, availability, and clinical value. The purpose of this study was to validate the technical accuracy and reliability of the PST technique in the lab and to report the outcomes of clinical application.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!