Thermoluminescent dosimeters (TLDs) were used to measure scatter radiation to the uninvolved breast in 30 patients who received tangential breast or chest-wall radiation with a technique in which the deep edges of the tangential fields were aligned. In most patients, measurements were made during the 1st week of radiation therapy, after port radiographs were obtained to ensure proper field position and accurate alignment of the posterior tangential field edges. Phantom measurements were made simultaneously with TLD measurements to systematically assess the scatter dose as a function of the wedging, number of fields, type of accelerator, beam energy, and bolus used in each treatment. For most patients, the scatter dose to the contralateral breast at a point on the skin 5 cm outside the edge of the medial beam was 8%-13% of the prescribed dose. However, higher doses (up to 36% of the therapeutic dose) were recorded in some patients.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiology.175.3.2343139DOI Listing

Publication Analysis

Top Keywords

scatter dose
12
tangential breast
8
uninvolved breast
8
breast
5
scatter
4
tangential
4
dose tangential
4
breast irradiation
4
irradiation uninvolved
4
breast thermoluminescent
4

Similar Publications

Zeatin Elicits Premature Erythrocyte Senescence Through Calcium and Oxidative Stress Mediated by the NOS/PKC/CK1α Signaling Axis.

Dose Response

January 2025

Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.

Cytokinins are plant hormones that regulate cell growth and differentiation. In particular, zeatin (ZTN) delays cellular senescence of human fibroblasts and keratinocytes and exhibits anticancer activity. Chemotherapy-induced anemia is a major side effect of anticancer therapy secondary to premature senescence of red blood cells (RBCs).

View Article and Find Full Text PDF

The impact of graphene oxide nanoparticles on the migratory behavior of metastatic human breast cancer cell, MDA-MB-231.

Naunyn Schmiedebergs Arch Pharmacol

January 2025

Neurophysiology Research Center, Cellular and Molecular Medicine Research Institute, Urmia University of Medical Sciences, Urmia, Iran.

Breast cancer (BC) with aggressive metastasis is a serious ongoing public health problem among women. Graphene oxide (GO) has an inhibitory effect on the migration rate and metastasis of BC cells, but its various aspects have not yet been explored. This paper aims to research into the effect of GO nanoparticles (GO-Np) on the migratory behavior of MDA-MB-231 as a metastatic human BC cell line.

View Article and Find Full Text PDF

Objective Applying carbon ion beams, which have high linear energy transfer and low scatter within the human body, to Spatially Fractionated Radiation Therapy (SFRT) could benefit the treatment of deep-seated or radioresistant tumors. This study aims to simulate the dose distributions of spatially fractionated beams (SFB) to accurately determine the delivered dose and model the cell survival rate following SFB irradiation. Approach Dose distributions of carbon ion beams are calculated using the Triple Gaussian Model.

View Article and Find Full Text PDF

Eye lens dosimetry: does the direction of rotation (vertical or horizontal) play a role in type testing?

J Radiol Prot

January 2025

Radiation Protection Dosimetry (6.3), Physikalisch-Technische Bundesanstalt, Braunschweig, NDS, GERMANY.

With the International Commission on Radiological Protection (ICRP) lowering the annual dose limit for the eye lens to 20 mSv, precise monitoring of eye lens exposure has become essential. The personal dose equivalent at a depth of 3 mm, Hp(3), is the measurement method for monitoring the dose to the lens of the eye. Traditional dosimetry methods primarily address lateral radiation exposure scenarios, where radiation approaches from the left or right, necessitating the rotation of the phantom during type testing around the vertical axis.

View Article and Find Full Text PDF

UV-irradiation is a stress factor for proteins, leading to disruption of their native structure. Test systems based on UV-irradiated proteins are relevant for researchers, as they allow working directly with damaged protein molecules, which can be important when studying the properties and mechanisms of action of various antiaggregation agents. The study of UV-irradiated proteins can also have applied significance, including medical.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!