Aim: To assess the usefulness of contrast-enhanced ultrasound (CEUS) during follow-up after percutaneous ablation therapy for hepatocellular carcinoma (HCC).
Methods: A total of 141 patients with HCCs who received percutaneous ablation therapy were assessed by paired follow-up CEUS and contrast-enhanced computed tomography (CECT). The follow-up scheme was designed prospectively and the intervals between CEUS and CECT examinations were less than 14 d. Both images of follow-up CEUS and CECT were reviewed by radiologists. The ablated lesions were evaluated and classified as local tumor progression (LTP) and LTP-free. LTP was defined as regrowth of tumor inside or adjacent to the successfully treated nodule. The detected new intrahepatic recurrences were also evaluated and defined as presence of intrahepatic new foci. On CEUS and CECT, LTP and new intrahepatic recurrence both were displayed as typical enhancement pattern of HCC (i.e., hyper-enhancing during the arterial phase and washout in the late phase). With CECT as the reference standard, the ability of CEUS in detecting LTP or new intrahepatic recurrence during follow-up was evaluated.
Results: During a follow-up period of 1-31 mo (median, 4 mo), 169 paired CEUS and CECT examinations were carried out for the 141 patients. For a total of 221 ablated lesions, 266 comparisons between CEUS and CECT findings were performed. Thirty-three LTPs were detected on CEUS whereas 40 LTPs were detected on CECT, there was significant difference (P < 0.001). In comparison with CECT, the numbers of false positive and false negative LTPs detected on CEUS were 6 and 13, respectively; the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and overall accuracy of CEUS in detecting LTPs were 67.5%, 97.4%, 81.8%, 94.4% and 92.3%, respectively. Meanwhile, 131 new intrahepatic recurrent foci were detected on CEUS whereas 183 were detected on CECT, there was also significant difference (P < 0.05). In comparison with CECT, the numbers of false positive and false negative intrahepatic recurrences detected on CEUS were 13 and 65, respectively; the sensitivity, specificity, PPV, NPV and overall accuracy of CEUS in detecting new intrahepatic recurrent foci were 77.7%, 92.0%, 92.4%, 76.7% and 84.0%, respectively.
Conclusion: The sensitivity of CEUS in detecting LTP and new intrahepatic recurrence after percutaneous ablation therapy is relatively low in comparison with CECT.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3574882 | PMC |
http://dx.doi.org/10.3748/wjg.v19.i6.855 | DOI Listing |
BMC Cancer
January 2025
Department of Ultrasonography, Nanjing Drum Tower Hospital, Drum Tower Clinical Medical College, Nanjing Medical University, Nanjing, 21009, China.
Background: Hepatic sarcomatoid carcinoma (HSC) and hepatic sarcoma (HS) are rare malignancies. Without pathology, the differential diagnosis between these two tumors is difficult due to their frequent overlaps in clinical presentations and imaging features. Currently, there are limited analyses about the ultrasound (US), contrast-enhanced ultrasound (CEUS) and contrast-enhanced computer tomography (CECT) characteristics of HSC and HS.
View Article and Find Full Text PDFInn Med (Heidelb)
January 2025
Innere Medizin I, Schwerpunkt Gastroenterologie, Sana Klinikum Lichtenberg, Berlin, Deutschland.
In patients with chronic inflammatory bowel disease (IBD), endoscopic techniques (including capsule techniques and balloon enteroscopy for the small intestine), ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) are primarily used as often complementary imaging techniques. Radiation exposure needs to be kept in mind when using CT and conventional X‑ray-techniques. Therefore, most importantly, ultrasound and MRI have changed the routine diagnostics of intestinal diseases.
View Article and Find Full Text PDFQuant Imaging Med Surg
December 2024
Ultrasound Medical Center, Lanzhou University Second Hospital, Lanzhou, China.
Abdom Radiol (NY)
December 2024
Department of Ultrasound, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou, China.
Objective: The 2019 Bosniak classification has improved the precise and detailed quantitative evaluation criteria, making the diagnosis of cystic renal masses (CRMs) more accurate and objective. This study addresses the clinical value of quantitative analysis and aims to investigate the feasibility of combining contrast-enhanced ultrasound (CEUS) with quantitative analysis for diagnosing Bosniak ≥ II CRMs.
Methods: We retrospectively obtained 58 CRMs with confirmed pathology, which underwent CEUS and Contrast-enhanced computer tomography (CECT) evaluations according to Bosniak classification between January 2013 and August 2024.
J Ultrasound Med
December 2024
Department of Ultrasound, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
Objectives: Current literature on imaging characteristics of hepatic inflammatory pseudotumor (HIPT) is limited. This study aimed to analyze the contrast-enhanced ultrasound (CEUS) features in HIPT and compare them with contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CEMRI).
Methods: A total of 83 patients with histologically proven HIPT from two medical institutions were included in this study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!