In a group of 38 patients with carcinoma of the uterine cervix, radiation doses were measured by thermoluminiscent dosimeters (TLDs) placed in catheters introduced into the urinary bladder and rectum during a 24 h uterovaginal application of 226Ra. The values of radiation doses registered by the TLDs were compared to those calculated from roentgenograms made after 24 h. To calculate the radiation doses, we used the program Brachy 9.3-C of the planning unit Evados (Siemens, FRG). Using nonparametric comparison tests, no statistically significant differences were found between the values of radiation doses registered by TLDs and those calculated after 24 h of uterovaginal application of 226Ra. Only in the oral part of the rectum, at a distance of 10 cm and above from the anal orifice, there were differences between doses measured by TLDs and those calculated from roentegenograms made after 24 h of brachytherapy. These differences were caused by the movement of the flexible catheters carrying the TLDs.

Download full-text PDF

Source

Publication Analysis

Top Keywords

radiation doses
20
carcinoma uterine
8
uterine cervix
8
doses measured
8
uterovaginal application
8
application 226ra
8
values radiation
8
doses registered
8
registered tlds
8
tlds calculated
8

Similar Publications

Dosimetric Planning Comparison for Left Ventricle Avoidance in Non-small Cell Lung Cancer Radiotherapy.

Cureus

December 2024

Physics and Engineering, London Regional Cancer Program, London, CAN.

Introduction: Radiation may unintentionally injure myocardial tissue, potentially leading to radiation-induced cardiac disease (RICD), with the net benefit of non-small cell lung cancer (NSCLC) radiotherapy (RT) due to the proximity of the lung and heart. RTOG-0617 showed a greater reduction in overall survival (OS) comparing higher doses to standard radiation doses in NSCLC RT. VHeart has been reported as an OS predictor in the first- and fifth-year follow-ups.

View Article and Find Full Text PDF

Background: Different doses of radiotherapy (RT) exert diverse effects on tumor immunity, although the precise irradiation method remains unknown. This study sought to elucidate the influence of combining different doses of RT with immune checkpoint inhibitors (ICIs) on the infiltration of CD8T cells within tumors, thereby augmenting the anti-tumor response.

Methods: Constructing a mouse model featuring bilateral lung cancer tumors subjected to high and low dose irradiation, the analysis of RNA transcriptome sequencing data and immunohistochemical validation for tumors exposed to various dosages guided the selection of the optimal low-dose irradiation scheme.

View Article and Find Full Text PDF

Background And Purpose: In lung stereotactic body radiation therapy (SBRT) using a breath-holding technique, displacement of tumor during breath-holding is rarely considered. This study used four-dimensional (4D) dose calculation with cine computed tomography (CT) to evaluate the impact of unexpected tumor position displacement during breath-holding on the target dose of lung volumetric modulated arc therapy (VMAT)-SBRT.

Materials And Methods: This study included 20 cases for which tumor position displacement during end-exhalation breath-holding (range: 0.

View Article and Find Full Text PDF

A preliminary study of linear accelerator-based spatially fractionated radiotherapy.

Front Oncol

January 2025

Department of Radiation Oncology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

Purpose: This study aimed to provide quantitative information for implementing Lattice radiotherapy (LRT) using a medical linear accelerator equipped with the Millennium 120 multi-leaf collimator (MLC). The research systematically evaluated the impact of varying vertex diameters and separations on dose distribution, peak-to-valley dose ratio (PVDR), and normal tissue dose.

Methods: A cylindrical Virtual Water™ phantom was used to create LRT treatments using the Eclipse version 16.

View Article and Find Full Text PDF

Trends in dentomaxillofacial radiology.

World J Radiol

January 2025

Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara 06500, Türkiye.

Oral and maxillofacial diagnostic imaging is of paramount importance in dental clinical diagnosis, treatment planning, and follow-up procedures. Periapical radiographic examination and numerous panoramic systems are used in routine clinical dental practice. Cone beam CT is widely used and currently the method of choice in oral and maxillofacial implantology, endodontics, maxillofacial surgery, periodontics, degenerative temporomandibular joint disease, orthodontics, airway studies, sleep disorders, and forensic dentistry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!