Objectives: Biomechanics is one of the main factors for achieving long-term success of implant supported prostheses. Long-term failures mostly depend on biomechanical complications. It is important to distinguish the effects of macro design of the implants.
Materials And Methods: In this study, the photoelastic response of four different types of implants that were inserted with different angulations were comparatively analyzed. The implant types investigated were screw cylinder (ITI, Straumann AG, Basel, Switzerland), stepped cylinder (Frialit2, Friadent GmbH, Manheim, Germany), root form (Camlog Rootline, Alatatec, Wilshelm, Germany), and cylindrical implant, with micro-threads on the implant neck (Astra, AstraTech, Mölndal, Sweden). In the test models, one of the implants was inserted straight, while the other one was aligned mesially with 15° angles. The superstructures were prepared as single crowns. A 150N loading was applied to the restorations throughout the test.
Results: A comparison of the implant designs showed that there were no significant differences between the straight implants; however, between the inclined implants, the most favorable stress distribution was seen with the stepped cylinder implants. The least favorable stress concentration was observed around the root formed implants. Microthreads around the implant neck appeared to be effective in a homogenous stress distribution. Observations showed that misaligned implants caused less stress than straight implants, but the stress concentrations were not homogenous.
Conclusion: As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4103/0970-9290.107346 | DOI Listing |
J Chem Inf Model
January 2025
Central European Institute of Technology, Masaryk University, Brno60200, Czech Republic.
Polymyxins, critical last-resort antibiotics, impact the distribution of membrane-bound divalent cations in the outer membrane of Gram-negative bacteria. We employed atomistic molecular dynamics simulations to model the effect of displacing these ions. Two polymyxin-sensitive and two polymyxin-resistant models of the outer membrane of were investigated.
View Article and Find Full Text PDFWomens Health (Lond)
January 2025
Unit of Oncological Gynecology, Centro di Riferimento Oncologico della Basilicata (IRCCS-CROB), Rionero in Vulture, Italy.
Background: The Coronavirus Disease (COVID-19) has had a significant impact on healthcare organizations, leading to a reduction in screening. The pandemic period has caused important psychological repercussions in the most fragile patients.
Objectives: This study aimed to assess the levels of depression, anxiety, peri-traumatic stress, and physical symptoms in patients undergoing colposcopy during the COVID-19 pandemic and to compare these data with the post-pandemic period.
Orthop Surg
January 2025
Orthopedics Department, Gongli Hospital of Shanghai Pudong New Area, Shanghai, China.
Objective: Soft tissue defects and postoperative wound healing complications related to calcaneus fractures may result in significant morbidity. The aim of this study was to investigate whether percutaneous minimally invasive screw internal fixation (PMISIF) can change this situation in the treatment of calcaneal fractures, and aimed to explore the mechanical effects of different internal fixation methods on Sanders type III calcaneal fractures through finite element analysis.
Methods: This retrospective analysis focused on 83 patients with Sanders II and III calcaneal fractures from March 2017 to March 2022.
BMC Oral Health
January 2025
Department of Endodontics, Faculty of Dentistry, Erciyes University, Kayseri, Turkey.
Background: This study assessed stress distributions in simulated mandibular molars filled with various materials after the removal of fractured instruments from the apical thirds of the root canals.
Methods: Finite element models of the mesial and distal root canals were created, where fractured instruments were assumed to be removed using a staging platform established with a modified Gates-Glidden bur (Woodpecker, Guangxi, P.R.
BMC Health Serv Res
January 2025
Indiana University School of Medicine, 410 W 10th St, Suite 2000A, Indianapolis, IN, 46202, USA.
Background: Individuals with Sickle Cell Disease (SCD) are a minoritized and marginalized community that have disparate health outcomes as a result of systemic racism and disease-related stigma. The purpose of this study was to determine the psychosocial risk factors for families caring for children with SCD at a pediatric SCD center through use of the Psychosocial Assessment Tool (PAT), a validated caregiver-report screener.
Methods: The PAT was administered annually during routine clinical visits and scored by the SCD Social Worker to provide tailored resources to families.