Introduction: The aim of the present study was to study the diagnostic efficacy of the percutaneous puncture of pancreatic tissue.

Material And Methods: A retrospective study was conducted on patients with suspicion of pancreatic neoplasm, and with a percutaneous biopsy of pancreatic tissue, from 2000 to 2011. For the statistical comparative analysis, the sample was stratified by tumour size: ≤ 3cm and > 3cm.

Results: A total of 90 biopsies were performed. Pancreatic neoplasm diagnosis was made in 47 cases (52%), with 16 false negatives (18%), no false positives, and chronic pancreatitis in 24 cases (27%). The efficacy of the test results were: an overall sensitivity of 75% (95% CI: 62%-85%), a specificity of 100% (95% CI: 87%-100%), a positive predictive value of 100% (95% CI: 92%-100%), and a negative predictive value of 63% (95% CI: 46%-77%). For tumour sizes ≤ 3cm the sensitivity was 70% (95% CI: 45%-88%), with a specificity of 100% (95% CI 66%-100%), a positive predictive value of 100% (95% CI: 76%-100%, and a negative predictive value 60% (95% CI: 32%-83%). For tumours greater than 3cm, the sensitivity was 88% (95% CI: 70%-98%), the specificity was 100% (95% CI: 75%-100%), with a positive predictive value of 100% (95% CI: 85%-100%) and a negative predictive value of 81% (95% CI: 54%-96%).

Conclusions: Pancreatic percutaneous biopsy efficacy was strongly determined by lesion size. For tumour sizes less than 3cm, the sensitivity and negative predictive value are unacceptably low, as negative results would not reliable.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ciresp.2012.10.019DOI Listing

Publication Analysis

Top Keywords

100% 95%
24
negative predictive
16
95%
12
specificity 100%
12
positive predictive
12
predictive 100%
12
pancreatic percutaneous
8
percutaneous puncture
8
pancreatic neoplasm
8
percutaneous biopsy
8

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!