Background: Graduated elastic compression (GEC) stockings have been demonstrated to reduce the morbidity associated with post-thrombotic syndrome. The ideal length or compression strength required to achieve this is speculative and related to physician preference and patient compliance. The aim of this study was to evaluate the hemodynamic performance of four different stockings and determine the patient's preference.

Methods: Thirty-four consecutive patients (40 legs, 34 male) with post-thrombotic syndrome were tested with four different stockings (Mediven plus open toe, Bayreuth, Germany) of their size in random order: class 1 (18-21 mm Hg) and class II (23-32 mm Hg), below-knee (BK) and above-knee thigh-length (AK). The median age, Venous Clinical Severity Score, Venous Segmental Disease Score, and Villalta scale were 62 years (range, 31-81 years), 8 (range, 1-21), 5 (range, 2-10), and 10 (range, 2-22), respectively. The C of C0-6EsAs,d,pPr,o was C0 = 2, C2 = 1, C3 = 3, C4a = 12, C4b = 7, C5 = 12, C6 = 3. Obstruction and reflux was observed on duplex in 47.5% legs, with deep venous reflux alone in 45%. Air plethysmography was used to measure the venous filling index (VFI), venous volume, and time to fill 90% of the venous volume. Direct pressure measurements were obtained while lying and standing using the PicoPress device (Microlab Elettronica, Nicolò, Italy). The pressure sensor was placed underneath the test stocking 5 cm above and 2 cm posterior to the medial malleolus. At the end of the study session, patients stated their preferred stocking based on comfort.

Results: The VFI, venous volume, and time to fill 90% of the venous volume improved significantly with all types of stocking versus no compression. In class I, the VFI (mL/s) improved from a median of 4.9 (range, 1.7-16.3) without compression to 3.7 (range, 0-14) BK (24.5%) and 3.6 (range, 0.6-14.5) AK (26.5%). With class II, the corresponding improvement was to 4.0 (range, 0.3-16.2) BK (18.8%) and 3.7 (range, 0.5-14.2) AK (24.5%). Median stocking pressure (mm Hg) as measured with the PicoPress in class I was 23 (range, 12-33) lying and 27 (range, 19-39) standing (P < .0005) and in class II was 28 (range, 21-40) lying and 32 (range, 23-46) standing (P < .0005). There was a significant but weak correlation (Spearman) between stocking interface pressure measured directly with the PicoPress and the VFI improvement (baseline VFI-compression VFI) at r = .237; P = .005. Twenty-one patients (legs) changed their preference of compression and 38% of these (8/21 patients, 9/21 legs) preferred an AK-GEC stocking.

Conclusions: Compression significantly improved all hemodynamic parameters on air plethysmography. However, the hemodynamic benefit did not significantly change with the class or length of stocking. These results support the liberal selection of a GEC stocking based on patient preference.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2013.01.003DOI Listing

Publication Analysis

Top Keywords

venous volume
16
range
13
post-thrombotic syndrome
12
hemodynamic performance
8
class
8
class length
8
patients legs
8
venous
8
years range
8
air plethysmography
8

Similar Publications

This document provides a comprehensive analysis of the use of point-of-care ultrasound in heart failure (HF), offering detailed recommendations on echocardiography, lung ultrasound, and venous ultrasound. These advanced imaging techniques allow for an accurate, detailed, and non-invasive evaluation of heart failure, facilitating rapid and effective clinical decision-making. Echocardiography enables a rapid assessment of cardiac function at the point of care, enhancing traditional physical examination and being essential for the management of heart failure (HF).

View Article and Find Full Text PDF

Retinal vein occlusion (RVO) is the leading cause of vision loss due to an obstruction in the retinal venous system. While RVO is often linked to thrombotic tendencies and coagulation abnormalities, the exact role of coagulation traits in its development is not fully understood. This study aims to investigate the potential causal relationship between coagulation traits and the risk of RVO by analyzing publicly available genome-wide association study (GWAS) summary statistics.

View Article and Find Full Text PDF

Background: Hemodynamic alterations in the spermatic vein are implicated in infertility among patients with varicocele (VC). Contrast-enhanced ultrasound (CEUS), a powerful tool for hemodynamic analysis, remains unexplored for VC. This study aimed to demonstrate the feasibility of using CEUS to evaluate spermatic vein hemodynamics in patients with VC and establish a clear correlation between specific hemodynamic patterns and impaired semen parameters.

View Article and Find Full Text PDF

An interactive simulator to deepen the understanding of Guyton's venous return curve.

J Physiol Sci

January 2025

Department of Hematology, Kitasato University School of Medicine, 1-15-1 Kitasato, Minami-Ku, 252-0374, Sagamihara, Kanagawa, Japan.

Mean circulatory filling pressure, venous return curve, and Guyton's graphical analysis are basic concepts in cardiovascular physiology. However, some medical students may not know how to view and interpret or understand them adequately. To deepen students' understanding of the graphical analysis, in place of having to perform live animal experiments, we developed an interactive cardiovascular simulator, as a self-learning tool, as a web application.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!