Objectives: The aim of the study was to investigate the dose-dependent effect of radiation on dental implant stability and osseointegration using a series of quantitative analyses.

Material And Methods: Six rabbits were randomly assigned to 15 and 30 Gy radiation groups. Each rabbit received radiation at the tibial and femoral metaphyseal region of left hind leg. The right leg was used as control. Implant surgery was performed on tibial and femoral metaphyses after 1 week. Totally 24 implants were inserted. The animals were killed at postoperative week four. Implant stability was measured using resonance frequency analysis. Ratio of bone volume to total volume (BV/TV), rate of bone growth, and bone-to-implant contact (BIC) were assessed using micro-computed tomography (micro-CT), fluorochrome labeling analysis, and histomorphometric analysis, respectively.

Results: After 4 weeks of healing, all implants were integrated (n = 6). Implant stability was significantly compromised by 15 Gy (P = 0.010) and 30 Gy (P = 0.025) of radiation. Radiation decreased BV/TV, and the significant effect was detected at the dose of 15 Gy (P = 0.008) and 30 Gy (P < 0.001). Bone growth in osseointegration was impaired by radiation. In 15 Gy group, the radiation side showed significant lower rate of bone growth than the control side at week 3 (P = 0.001), while the undistinguishable signals on 30 Gy radiation side suggested the low rate of new bone formation at each time point. Histomorphological BIC had no significant difference between 15 Gy control side and 15 Gy radiation side. 30 Gy radiation side showed a significantly lower BIC than 30 Gy control side (P < 0.001) as well as 15 Gy radiation side (P < 0.001).

Conclusions: Implant stability and osseointegration were compromised by radiation. Radiation compromised osseointegration in a dose-dependent manner.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.12116DOI Listing

Publication Analysis

Top Keywords

radiation side
20
implant stability
16
radiation
13
rate bone
12
bone growth
12
control side
12
dose-dependent radiation
8
stability osseointegration
8
tibial femoral
8
radiation radiation
8

Similar Publications

Unlabelled: Despite the remarkably high antioxidant activity of tocopherols, their applications in the food industry are limited because of their instability under various conditions. Complexes of α-tocopherol (α-TQ) or α-tocopheryl acetate (α-TQA) with β-cyclodextrin (β-CD) or starch were prepared and characterized by UV-vis, IR and thermal analysis. Oxidative stability of α-TQ and α-TQA against HO was 74.

View Article and Find Full Text PDF

This is a case of a young, 20-year-old, male Navy recruit who was admitted to our healthcare facility with intermittent atypical chest pain and limiting exertional symptoms and was diagnosed with myocardial bridging (MB) as the most likely etiology of his chest after the complete cardiac workup, leading to his career limitations due to potential risks. Our patient presented with atypical chest pain and limiting exertional symptoms. Chest pain was non-radiating.

View Article and Find Full Text PDF

Plasmonic heating by indium tin oxide nanoparticles: spectrally enabling decoupled near-infrared theranostics.

Nanoscale

January 2025

Nanomaterials for BioImaging Group (nanoBIG), Departamento de Física de Materiales, Universidad Autónoma de Madrid (UAM), Madrid 28049, Spain.

All-optical theranostic systems are sought after in nanomedicine, since they combine in a single platform therapeutic and diagnostic capabilities. Commonly in these systems the therapeutic and diagnostic/imaging functions are accomplished with plasmonic photothermal agents and luminescent nanoparticles (NPs), respectively. For maximized performance and minimized side effects, these two modalities should be independently activated, , in a decoupled way, using distinct near infrared (NIR) wavelengths: a radiation window wherein photon-tissue interaction is reduced.

View Article and Find Full Text PDF

The BioSentinel CubeSat was deployed on the Artemis-I mission in November 2022 and has been continuously transmitting physical measurements of the space radiation environment since that time. Just before mission launch, we published computational model predictions of the galactic cosmic ray exposure expected inside BioSentinel for multiple locations and configurations. The predictions utilized models for the ambient galactic cosmic ray environment, radiation physics and transport, and BioSentinel geometry.

View Article and Find Full Text PDF

Passive Radiant Cooling and Heating are green and sustainable methods of radiant heat management without consuming additional energy. However, the absorption of sunlight and poor insulation of materials can reduce radiative cooling and also affect radiative heating performance. Herein, we have constructed porous hierarchical dual-mode silk nanofibrous aerogel (SNF) films with high mechanical toughness and stability using silk nanofibers/GO.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!