A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prospective clinical study of a novel biodegradable sub-acromial spacer in treatment of massive irreparable rotator cuff tears. | LitMetric

Purpose: The purposes of this prospective non-randomized study were to confirm the feasibility of the biodegradable sub-acromial spacer (InSpace™) implantation in patients with massive irreparable rotator cuff tear and to determine the safety profile and functional results 3 years post-implantation.

Methods: Twenty patients were implanted with the InSpace™ device and assessed up to 3 years of post-implantation. Improvement in shoulder function was assessed using Constant score, while ease of use of the system was recorded by surgeons as were device-related adverse events.

Results: Twenty patients were available for assessment. Implantation was performed arthroscopically in all patients, and a range of deployment time was 2-20 min. The mean total Constant score increased from 33.4 to 65.4 points at 3 years. There was an improvement of 6.4 points in subjective pain score which commenced at 1 week post-operatively and was sustained until 3 years of follow-up. Also activities of daily living and motions commenced improvement by 9.4 and 7.7 points, respectively. Improvement in power was only evident at 18 months of follow-up but was sustained at 3 years.

Conclusions: Arthroscopic deployment of a co-polymer biodegradable spacer (balloon) into the sub-acromial space for an irreparable rotator cuff tear was found to be low-risk and simple procedure associated with improvement in shoulder function and low rate of complications.

Level Of Evidence: IV; therapeutic case series.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00590-012-0981-4DOI Listing

Publication Analysis

Top Keywords

irreparable rotator
12
rotator cuff
12
biodegradable sub-acromial
8
sub-acromial spacer
8
massive irreparable
8
cuff tear
8
twenty patients
8
improvement shoulder
8
shoulder function
8
constant score
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!